Hypochlorous Acid Sensor using Boron-Doped Diamond Electrode in Physiological pH Solution

Nadiatus Silmi, T. Ivandini, Endang Asijati W
{"title":"Hypochlorous Acid Sensor using Boron-Doped Diamond Electrode in Physiological pH Solution","authors":"Nadiatus Silmi, T. Ivandini, Endang Asijati W","doi":"10.1109/ISSIMM.2018.8727635","DOIUrl":null,"url":null,"abstract":"Electrochemical behavior of hypochlorous acid (HClO) have been studied at boron-doped diamond (BDD) electrodes in physiological pH solution. The electrochemical measurements were performed in one-compartment electrochemical cell using cyclic voltammetry technique. A solution of 0.5 M phosphate buffer solution has been selected as the supporting electrolyte. Cyclic voltammograms of NaClO standard solutions showed the best response at optimum pH of 6.6 at the potential reduction of +0.1 V. Linear calibration curve ($\\mathbf{R}^{2}=0.9953$) can be achieved at a NaClO concentration range from 1.68 to 5.86 mM with an estimated limit of detection (LOD) of 0.46 mM.","PeriodicalId":178365,"journal":{"name":"2018 3rd International Seminar on Sensors, Instrumentation, Measurement and Metrology (ISSIMM)","volume":"183 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 3rd International Seminar on Sensors, Instrumentation, Measurement and Metrology (ISSIMM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSIMM.2018.8727635","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Electrochemical behavior of hypochlorous acid (HClO) have been studied at boron-doped diamond (BDD) electrodes in physiological pH solution. The electrochemical measurements were performed in one-compartment electrochemical cell using cyclic voltammetry technique. A solution of 0.5 M phosphate buffer solution has been selected as the supporting electrolyte. Cyclic voltammograms of NaClO standard solutions showed the best response at optimum pH of 6.6 at the potential reduction of +0.1 V. Linear calibration curve ($\mathbf{R}^{2}=0.9953$) can be achieved at a NaClO concentration range from 1.68 to 5.86 mM with an estimated limit of detection (LOD) of 0.46 mM.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
生理pH溶液中掺硼金刚石电极次氯酸传感器
研究了次氯酸(HClO)在生理pH溶液中在掺硼金刚石(BDD)电极上的电化学行为。采用循环伏安法在单室电化学电池中进行电化学测量。选择0.5 M的磷酸盐缓冲溶液作为支撑电解质。氯化钠标准溶液的循环伏安图显示,在pH为6.6时,电位降低+0.1 V时反应最佳。在NaClO浓度范围为1.68 ~ 5.86 mM时,可获得线性校准曲线($\mathbf{R}^{2}=0.9953$),估计检出限(LOD)为0.46 mM。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design and Manufacturing of Motor-Tendon Actuator for a Soft Starfish-Like Robot Gray Scale and Edge Detecting Method To Extract Raw Data in The Diffusivity Measurement System Omnidirectional Sensing for Escaping Local Minimum on Potential Field Mobile Robot Path Planning in Corridors Environment Enhancing Temperature Sensitivity for The SMS Fiber Structure Temperature Sensor Copyright
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1