A neutron television camera detector.

Brookhaven symposia in biology Pub Date : 1976-05-01
U W Arndt, D J Gilmore
{"title":"A neutron television camera detector.","authors":"U W Arndt,&nbsp;D J Gilmore","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The system under development has a large counting rate capability; this is extremely important where the total background count exceeds the total counts in the signals of interest. Its spatial resolution is of the order of one mm, which is perfectly adequate for neutron work, while the screen size of 400 mm is reasonable. The main limitation of the system is its limited counting efficiency, and this is directly attributable to the optical self-absorption of the neutron phosphor. Any newly developed transparent phosphor with the same light output would immediately change the situation. The success of the electronics hardware in reducing random noise is demonstrated in Figure 3, which shows in the bottom trace the live video output when the input to the system is a grey-scale test chart. The top trace is the output after the image has been digitally integrated. Figures 4 and 5 show the monitor outputs of the see articles x-ray system with a \"still\" diffraction pattern of a crystal of GPD (glyceraldehyde-3-phosphate dehydrogenase). Figure 4 is a photograph of the \"live\" video display, and Figure 5 is the digitally summed image. All coherent noise in the system, i.e., all noise synchronized with the TV scans has to be kept lower than the first bit threshold. However, this requirement can be relaxed when dealing with diffraction patterns, such as those from single crystals, for which a local background is subtracted from the pattern.</p>","PeriodicalId":75624,"journal":{"name":"Brookhaven symposia in biology","volume":" 27","pages":"VIII16-VIII23"},"PeriodicalIF":0.0000,"publicationDate":"1976-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brookhaven symposia in biology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The system under development has a large counting rate capability; this is extremely important where the total background count exceeds the total counts in the signals of interest. Its spatial resolution is of the order of one mm, which is perfectly adequate for neutron work, while the screen size of 400 mm is reasonable. The main limitation of the system is its limited counting efficiency, and this is directly attributable to the optical self-absorption of the neutron phosphor. Any newly developed transparent phosphor with the same light output would immediately change the situation. The success of the electronics hardware in reducing random noise is demonstrated in Figure 3, which shows in the bottom trace the live video output when the input to the system is a grey-scale test chart. The top trace is the output after the image has been digitally integrated. Figures 4 and 5 show the monitor outputs of the see articles x-ray system with a "still" diffraction pattern of a crystal of GPD (glyceraldehyde-3-phosphate dehydrogenase). Figure 4 is a photograph of the "live" video display, and Figure 5 is the digitally summed image. All coherent noise in the system, i.e., all noise synchronized with the TV scans has to be kept lower than the first bit threshold. However, this requirement can be relaxed when dealing with diffraction patterns, such as those from single crystals, for which a local background is subtracted from the pattern.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一个中子电视摄像机探测器。
正在开发的系统具有较大的计数率能力;当总背景计数超过感兴趣的信号总数时,这一点非常重要。其空间分辨率约为1 mm,完全可以满足中子工作,而400 mm的屏幕尺寸是合理的。该系统的主要限制是计数效率有限,这直接归因于中子荧光粉的光学自吸收。任何新开发的具有相同光输出的透明荧光粉都会立即改变这种情况。图3展示了电子硬件在降低随机噪声方面的成功,在底部的跟踪图中显示了当系统输入是灰度测试图时的实时视频输出。顶部的迹线是图像经过数字集成后的输出。图4和5显示了带有GPD(甘油醛-3-磷酸脱氢酶)晶体“静止”衍射图案的x射线系统的监视器输出。图4是“实时”视频显示的照片,图5是数字求和图像。系统中的所有相干噪声,即与电视扫描同步的所有噪声必须保持在低于第一比特阈值的水平。然而,这一要求可以放宽,当处理衍射图案,如那些从单晶,为局部背景从图案减去。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The meaning of stability. Mechanisms of DNA uptake by cells. Chromosome-mediated gene transfer with resultant expression and integration of the transferred genes in eukaryotic cells. Gene transfer experiments in Neurospora. Expression of the structural gene for catabolic dehydroquinase of Neurospora crassa in Escherichia coli K12.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1