Fly's eye: a counting camera for thermal neutrons-some applications, problems, and prospects.

Brookhaven symposia in biology Pub Date : 1976-05-01
J P Davidson
{"title":"Fly's eye: a counting camera for thermal neutrons-some applications, problems, and prospects.","authors":"J P Davidson","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An area detector for thermal neutrons based on image intensification techniques has been described. Some capabilities and limitations of the detection system have been discussed. Among the former are high spatial resolution, high instantaneous counting rate, electronic zoom, time-gating, and integration. The detector is limited in that the maximum counting rate for a resolution element is 60 regularly spaced counts per second. Also, the nonuniformity of response over the detector puts a limit on the useful size and necessitates point-by-point calibration. In addition, a higher efficiency for neutron detection would be desirable. Some typical applications of the system are crystal inspection, neutron magnetic diffraction topography, and searches for temperature-induced changes in diffraction patterns. The future application of solid-state television sensors and microchannel-plate intensifiers to improve the system were briefly mentioned.</p>","PeriodicalId":75624,"journal":{"name":"Brookhaven symposia in biology","volume":" 27","pages":"VIII3-VIII15"},"PeriodicalIF":0.0000,"publicationDate":"1976-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brookhaven symposia in biology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An area detector for thermal neutrons based on image intensification techniques has been described. Some capabilities and limitations of the detection system have been discussed. Among the former are high spatial resolution, high instantaneous counting rate, electronic zoom, time-gating, and integration. The detector is limited in that the maximum counting rate for a resolution element is 60 regularly spaced counts per second. Also, the nonuniformity of response over the detector puts a limit on the useful size and necessitates point-by-point calibration. In addition, a higher efficiency for neutron detection would be desirable. Some typical applications of the system are crystal inspection, neutron magnetic diffraction topography, and searches for temperature-induced changes in diffraction patterns. The future application of solid-state television sensors and microchannel-plate intensifiers to improve the system were briefly mentioned.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
苍蝇的眼睛:热中子计数照相机——一些应用、问题和前景。
介绍了一种基于图像增强技术的热中子区域探测器。讨论了该检测系统的一些性能和局限性。前者包括高空间分辨率、高瞬时计数率、电子变焦、时间门控和集成。检测器的限制在于分辨率元件的最大计数率为每秒60个有规则间隔的计数。此外,探测器响应的不均匀性限制了有用的尺寸,需要逐点校准。此外,需要更高的中子探测效率。该系统的一些典型应用是晶体检测、中子磁衍射形貌和寻找温度引起的衍射图变化。简要介绍了固态电视传感器和微通道板增强器的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The meaning of stability. Mechanisms of DNA uptake by cells. Chromosome-mediated gene transfer with resultant expression and integration of the transferred genes in eukaryotic cells. Gene transfer experiments in Neurospora. Expression of the structural gene for catabolic dehydroquinase of Neurospora crassa in Escherichia coli K12.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1