Outcomes of intentional perforation of the maxillary sinus floor during implant placement: A single-center, prospective study in 57 subjects

Vallabhdas Santosh, Parushuram Bhukya, Bhagyasri Medisetty, V. Rampalli, P. Kumaar
{"title":"Outcomes of intentional perforation of the maxillary sinus floor during implant placement: A single-center, prospective study in 57 subjects","authors":"Vallabhdas Santosh, Parushuram Bhukya, Bhagyasri Medisetty, V. Rampalli, P. Kumaar","doi":"10.4103/jdi.jdi_24_19","DOIUrl":null,"url":null,"abstract":"Context: An essential precondition for successful implant therapy is the presence of an adequate quantity and quality of bone. Aims: The purpose of this study was to radiographically evaluate the bone formation around the dental implants which were placed at different depths into the maxillary sinus by intentional perforation of maxillary sinus floor during implant placement and its effect on implant survival rate. Settings and Design: A total of 86 implants of varying dimensions were placed in maxillary premolar and molar region by intentional perforation of the maxillary sinus floor during implant placement in 57 patients. Subjects and Methods: They were divided into three groups G1, G2, and G3 based on the depth of penetration into the maxillary sinus (region by [IS] compartment) (IS-G1-1 mm; G2-2 mm; G3-3 mm). The following parameters were evaluated-torque, bone density, and bone fill after 6 months of implant placement. Statistical Analysis Used: The comparison among groups for repeated measures data was made by ANOVA repeated measures test. The correlation between two parameters, i.e., torque and bone fill was done by Karl Pearson's correlation test Results: No significant differences were observed among the three groups for torque, bone fill, and bone density from baseline to 6 months. The correlation between torque and bone fill revealed R = 0.198, P = 0.293 which was statistically insignificant Conclusions: There were minimal failure rates and complications observed at the end of the study period. The survival rate of implants was not influenced either by torque or by the depth of penetration of implant into the maxillary sinus.","PeriodicalId":212982,"journal":{"name":"Journal of Dental Implants","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jdi.jdi_24_19","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Context: An essential precondition for successful implant therapy is the presence of an adequate quantity and quality of bone. Aims: The purpose of this study was to radiographically evaluate the bone formation around the dental implants which were placed at different depths into the maxillary sinus by intentional perforation of maxillary sinus floor during implant placement and its effect on implant survival rate. Settings and Design: A total of 86 implants of varying dimensions were placed in maxillary premolar and molar region by intentional perforation of the maxillary sinus floor during implant placement in 57 patients. Subjects and Methods: They were divided into three groups G1, G2, and G3 based on the depth of penetration into the maxillary sinus (region by [IS] compartment) (IS-G1-1 mm; G2-2 mm; G3-3 mm). The following parameters were evaluated-torque, bone density, and bone fill after 6 months of implant placement. Statistical Analysis Used: The comparison among groups for repeated measures data was made by ANOVA repeated measures test. The correlation between two parameters, i.e., torque and bone fill was done by Karl Pearson's correlation test Results: No significant differences were observed among the three groups for torque, bone fill, and bone density from baseline to 6 months. The correlation between torque and bone fill revealed R = 0.198, P = 0.293 which was statistically insignificant Conclusions: There were minimal failure rates and complications observed at the end of the study period. The survival rate of implants was not influenced either by torque or by the depth of penetration of implant into the maxillary sinus.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
种植体放置时上颌窦底故意穿孔的结果:一项涉及57名受试者的单中心前瞻性研究
背景:种植体治疗成功的一个基本前提是有足够数量和质量的骨。目的:本研究的目的是通过在上颌窦底故意穿孔放置种植体时,在不同深度放置种植体周围的骨形成及其对种植体成活率的影响。设置和设计:在种植过程中,57例患者通过上颌窦底故意穿孔,将86颗不同尺寸的种植体放置在上颌前磨牙和磨牙区域。对象与方法:根据入颌窦深度(经[IS]隔室区域)分为G1、G2、G3三组(IS-G1-1 mm;G2-2 mm;G3-3毫米)。评估以下参数-种植体放置6个月后的扭矩、骨密度和骨填充。统计分析方法:重复测量资料组间比较采用方差分析重复测量检验。扭矩与骨填充两项参数的相关性采用Karl Pearson相关检验。结果:三组间扭矩、骨填充、骨密度从基线至6个月无显著差异。转矩与骨填充的相关性R = 0.198, P = 0.293,差异无统计学意义。结论:研究结束时的失败率和并发症均为最小。种植体的成活率不受扭矩和种植体进入上颌窦的深度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Piezo osteotomy with all-on-4 implants to enable a full-arch rehabilitation A comparative evaluation of bite pressure between single implant prosthesis and natural teeth: An in-vivo study Two implant-retained mandibular overdenture using locator attachment – A clinical report Systemic medications and implant success: Is there a link? Part three: The effects of antiresorptive and anti-angiogenic agents on the outcome of implant therapy Gender-based predilection for the microbial load of Aggregatibacter actinomycetemcomitans present in anterior versus posterior implant sites: A preliminary observational study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1