More than power from wind: Emperical data from a wind farm providing power-frequency response and automatic generation control

E. Rebello, Marianne Rodgers, David Stanford, M. Fischer, Mouhcine Akki
{"title":"More than power from wind: Emperical data from a wind farm providing power-frequency response and automatic generation control","authors":"E. Rebello, Marianne Rodgers, David Stanford, M. Fischer, Mouhcine Akki","doi":"10.1109/PESGM48719.2022.9916898","DOIUrl":null,"url":null,"abstract":"Modern wind turbines are capable of providing more than low-cost energy - they are able to provide a wide array of ancillary services that can contribute to the stability of a changing grid. This work evaluates the performance of Enercon's E-82 wind turbines in providing two ancillary services - power-frequency response (frequency-watt response) and automatic generation control (AGC). Empirical data is gathered at the 50.6 MW Nuttby Mountain wind farm in Nova Scotia, Canada that consists of twenty two IEC Type 4 turbines. AGC data is from the entire farm responding as a single unit while power-frequency data is from a single wind turbine. We document and analyse the wind farm's ability to curtail power output in response to grid frequency increases at varying power levels and also present forty five minutes of AGC data. Empirical data such as these are useful to system operators in determining how to best utilise their existing wind power fleets. We report good performance with both ancillary services. Mean error for the power-frequency data is approximately 2% of rated turbine power. Performance scores for AGC are 97% via the California ISO method and 87% via the Midcontinent ISO method.","PeriodicalId":388672,"journal":{"name":"2022 IEEE Power & Energy Society General Meeting (PESGM)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Power & Energy Society General Meeting (PESGM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM48719.2022.9916898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Modern wind turbines are capable of providing more than low-cost energy - they are able to provide a wide array of ancillary services that can contribute to the stability of a changing grid. This work evaluates the performance of Enercon's E-82 wind turbines in providing two ancillary services - power-frequency response (frequency-watt response) and automatic generation control (AGC). Empirical data is gathered at the 50.6 MW Nuttby Mountain wind farm in Nova Scotia, Canada that consists of twenty two IEC Type 4 turbines. AGC data is from the entire farm responding as a single unit while power-frequency data is from a single wind turbine. We document and analyse the wind farm's ability to curtail power output in response to grid frequency increases at varying power levels and also present forty five minutes of AGC data. Empirical data such as these are useful to system operators in determining how to best utilise their existing wind power fleets. We report good performance with both ancillary services. Mean error for the power-frequency data is approximately 2% of rated turbine power. Performance scores for AGC are 97% via the California ISO method and 87% via the Midcontinent ISO method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不仅仅是风能:来自风力发电场的经验数据,提供工频响应和自动发电控制
现代风力涡轮机能够提供的不仅仅是低成本的能源,它们还能够提供一系列广泛的辅助服务,有助于稳定不断变化的电网。这项工作评估了Enercon E-82风力涡轮机的性能,提供了两项辅助服务——工频响应(频率-瓦响应)和自动发电控制(AGC)。经验数据是在加拿大新斯科舍省的50.6兆瓦纳特比山风电场收集的,该风电场由22台IEC 4型涡轮机组成。AGC数据来自整个农场作为一个单元响应,而工频数据来自单个风力涡轮机。我们记录并分析了风电场在不同功率水平下响应电网频率增加而减少电力输出的能力,并提供了45分钟的AGC数据。诸如此类的经验数据对系统运营商在决定如何最好地利用现有风力发电机组方面非常有用。我们报告了两项辅助服务的良好表现。工频数据的平均误差约为额定涡轮功率的2%。通过加州ISO方法,AGC的表现得分为97%,通过中大陆ISO方法,得分为87%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Novel Framework for the Operational Reliability Evaluation of Integrated Electric Power-Gas Networks The Human Factors of Public Safety Power Shutoff (PSPS) Decision-Making: Improving Decision Support Displays Data-Driven Model Reduction of the Moving Boundary Heat Pump Dynamic Model Privacy-Preserving Feasibility Assessment for P2P Energy Trading and Storage Integration Distribution System Planning for Growth in Residential Electric Vehicle Adoption
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1