Upgrade of the far-infrared interferometer and polarimeter on TEXTOR

A. Cosler, E. Kemmereit, H. Soltwisch
{"title":"Upgrade of the far-infrared interferometer and polarimeter on TEXTOR","authors":"A. Cosler, E. Kemmereit, H. Soltwisch","doi":"10.1109/FUSION.1993.518290","DOIUrl":null,"url":null,"abstract":"A combined HCN laser interferometer/polarimeter comprising nine vertical probing beams has been in routine use on TEXTOR for simultaneous measurements of the electron density and poloidal magnetic field distributions and for feedback control of the gas injection and horizontal plasma positioning systems. Motivated by a growing interest in rapid changes of the internal magnetic field structure as well as by the need for reliable control diagnostics of the plasma shape and vertical position under long pulse conditions, the instrument has been complemented recently with a horizontal channel. The upgrading has been achieved by minor modifications of the existing optical arrangement and mechanical structure without impairing the function of the original apparatus. In this contribution, the constraints and technical solutions for the alterations are outlined and the improved performance is illustrated by practical examples.","PeriodicalId":365814,"journal":{"name":"15th IEEE/NPSS Symposium. Fusion Engineering","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"15th IEEE/NPSS Symposium. Fusion Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FUSION.1993.518290","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A combined HCN laser interferometer/polarimeter comprising nine vertical probing beams has been in routine use on TEXTOR for simultaneous measurements of the electron density and poloidal magnetic field distributions and for feedback control of the gas injection and horizontal plasma positioning systems. Motivated by a growing interest in rapid changes of the internal magnetic field structure as well as by the need for reliable control diagnostics of the plasma shape and vertical position under long pulse conditions, the instrument has been complemented recently with a horizontal channel. The upgrading has been achieved by minor modifications of the existing optical arrangement and mechanical structure without impairing the function of the original apparatus. In this contribution, the constraints and technical solutions for the alterations are outlined and the improved performance is illustrated by practical examples.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
TEXTOR上远红外干涉仪和偏振仪的升级
由9个垂直探测光束组成的组合式HCN激光干干仪/偏振计已在TEXTOR上常规使用,用于同时测量电子密度和极向磁场分布,并用于气体注入和水平等离子体定位系统的反馈控制。由于人们对内部磁场结构的快速变化越来越感兴趣,以及对长脉冲条件下等离子体形状和垂直位置的可靠控制诊断的需要,该仪器最近又增加了一个水平通道。升级是通过对现有光学排列和机械结构进行微小修改而实现的,而不会损害原始设备的功能。在这篇文章中,概述了改造的限制和技术解决方案,并通过实际例子说明了性能的提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Application of sidestream recycle to the separation of hydrogen isotopes by cryogenic distillation Repair of poloidal field magnets on Alcator C-Mod Beam species mix as a function of DIII-D neutral beam ion source operation parameters Design of the TPX limiter and armor components Design, control and operation of the vacuum and gas systems for Alcator C-Mod
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1