A Method for Small Number of Human Sperm Cryopreservation

Xiangli Niu, Huang Hua, Yi Mo, Yan Sun, Weihua Wang
{"title":"A Method for Small Number of Human Sperm Cryopreservation","authors":"Xiangli Niu, Huang Hua, Yi Mo, Yan Sun, Weihua Wang","doi":"10.5772/intechopen.98674","DOIUrl":null,"url":null,"abstract":"Recently, some sperm vitrification devices were developed to simplify the procedures to freeze small number of human sperm. In the present study, we used these devices to further examine some factors that affect sperm motility after fast freezing. Experiments were designed to examine the effects of 1) direct immersion of the devices to liquid nitrogen and indirect immersion of the devices to liquid nitrogen in which the devices were sealed in cryogenic storage vials; 2) different freezing volumes (1–5 μl); 3) different equilibration times (1–5 min); and 4) different ratio of freezing solution (0,1-5,1) on post thawing sperm motility. It was found that fast sperm freezing in the sealed vials had high post thawing sperm motility (91.3–93.7% of recovered sperm motility rates) while direct immersion of the devices to liquid nitrogen had 0% post thawing sperm motility. No differences in the recovered sperm motility rates were observed between different freezing solution volumes (87.4–90.5%), different equilibration times (89.5–94.0%), and different freezing solution ratios (90.8–94.6%). However, only 6.8% of recovered sperm motility rate was obtained if sperm were frozen in the medium without sperm freezing solution. These results indicate that human sperm can be rapidly frozen after the devices are sealed in the vials with different equilibration time in the medium containing sperm freezing solution. High post thawing sperm motility can be recovered with this method so that ~90% of sperm are usable after freezing.","PeriodicalId":415770,"journal":{"name":"Infertility and Assisted Reproduction [Working Title]","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infertility and Assisted Reproduction [Working Title]","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5772/intechopen.98674","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Recently, some sperm vitrification devices were developed to simplify the procedures to freeze small number of human sperm. In the present study, we used these devices to further examine some factors that affect sperm motility after fast freezing. Experiments were designed to examine the effects of 1) direct immersion of the devices to liquid nitrogen and indirect immersion of the devices to liquid nitrogen in which the devices were sealed in cryogenic storage vials; 2) different freezing volumes (1–5 μl); 3) different equilibration times (1–5 min); and 4) different ratio of freezing solution (0,1-5,1) on post thawing sperm motility. It was found that fast sperm freezing in the sealed vials had high post thawing sperm motility (91.3–93.7% of recovered sperm motility rates) while direct immersion of the devices to liquid nitrogen had 0% post thawing sperm motility. No differences in the recovered sperm motility rates were observed between different freezing solution volumes (87.4–90.5%), different equilibration times (89.5–94.0%), and different freezing solution ratios (90.8–94.6%). However, only 6.8% of recovered sperm motility rate was obtained if sperm were frozen in the medium without sperm freezing solution. These results indicate that human sperm can be rapidly frozen after the devices are sealed in the vials with different equilibration time in the medium containing sperm freezing solution. High post thawing sperm motility can be recovered with this method so that ~90% of sperm are usable after freezing.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种少量人精子冷冻保存方法
最近,一些精子玻璃化装置被开发出来,以简化冷冻少量人类精子的程序。在本研究中,我们使用这些装置来进一步研究快速冷冻后影响精子活力的一些因素。实验设计考察了1)直接浸入液氮和间接浸入液氮并密封在低温小瓶中对器件的影响;2)不同冷冻体积(1 ~ 5 μl);3)不同的平衡时间(1-5分钟);4)不同冷冻液配比(0,1-5,1)对解冻后精子活力的影响。结果发现,在密封小瓶中快速冷冻的精子具有较高的解冻后精子活力(恢复精子活力率为91.3 ~ 93.7%),而直接浸泡在液氮中解冻后精子活力为0%。不同冷冻液体积(87.4-90.5%)、不同平衡次数(89.5-94.0%)和不同冷冻液比例(90.8-94.6%)对恢复精子活力率无显著影响。然而,如果精子在不含精子冷冻液的培养基中冷冻,精子活力恢复率仅为6.8%。这些结果表明,在含有精子冷冻液的培养基中,将该装置密封在不同平衡时间的小瓶中,可以实现人类精子的快速冷冻。该方法可恢复高的解冻后精子活力,约90%的精子在冷冻后仍可使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of Heavy Metals on Tyrosine Kinases Signaling during Sperm Capacitation Understanding Male Infertility for Promising ART You Have a New Super Power: Ethics of oocyte Cryopreservation Fibroids and Infertility Efficiency of Autologous Egg Cryopreservation: Eight Years’ Experiences and Clinical Outcomes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1