The evaluation of simultaneous faults on three-phase systems

J. Mortlock
{"title":"The evaluation of simultaneous faults on three-phase systems","authors":"J. Mortlock","doi":"10.1049/JI-2.1947.0061","DOIUrl":null,"url":null,"abstract":"Equivalent circuits representing simultaneous dissymmetries on 3-phase systems have been treated previously, 1, 2, 3 but the analysis has been purely mathematical and the ultimate evaluations have been formal. In this paper the more direct method of superposition is employed, as this retains the physical aspect and in general reduces the labour of computation; it also has the indirect advantage that the faults are developed in proper sequence.All possible combinations of two dissymmetries are analysed, with the exception of simultaneous open-circuits. The results are tabulated suitably for direct computation.The primary operation is to reduce the symmetrical-component sequence networks of a given system to the simplest arrangement of impedances between the source and the dissymmetry locations. The networks are then interconnected so that the pertinent constraints between the sequence currents and voltages are complied with at both locations. In general the interconnections at one location can be made direct, whereas at the other magnetic coupling will be required. The constraints and the direct- and magnetically-coupled interconnections for all types of faults and open-circuits are tabulated.The interconnections for any particular dissymmetry can be introduced for faults by the closure, and for open-circuits by the opening, of a switch. The procedure employed is, with the switch (S1) controlling the magnetic interconnections open, to close or open the switch (S2) controlling the direct interconnections, and to determine the current and voltage distributions throughout the network, in particular the voltage across S1. The current or voltage distribution which would be due to the closure of S1 is then determined by an operation equivalent to closing it, i.e. by applying across its terminals a voltage equal and opposite to that determined from the operation of S2. The actual current or voltage distribution for the simultaneous dissymmetries is then the vector sum of the distributions due to the closure (or opening) of S2 and the equivalent closure of S1.","PeriodicalId":307627,"journal":{"name":"Journal of the Institution of Electrical Engineers - Part II: Power Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1947-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Institution of Electrical Engineers - Part II: Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/JI-2.1947.0061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Equivalent circuits representing simultaneous dissymmetries on 3-phase systems have been treated previously, 1, 2, 3 but the analysis has been purely mathematical and the ultimate evaluations have been formal. In this paper the more direct method of superposition is employed, as this retains the physical aspect and in general reduces the labour of computation; it also has the indirect advantage that the faults are developed in proper sequence.All possible combinations of two dissymmetries are analysed, with the exception of simultaneous open-circuits. The results are tabulated suitably for direct computation.The primary operation is to reduce the symmetrical-component sequence networks of a given system to the simplest arrangement of impedances between the source and the dissymmetry locations. The networks are then interconnected so that the pertinent constraints between the sequence currents and voltages are complied with at both locations. In general the interconnections at one location can be made direct, whereas at the other magnetic coupling will be required. The constraints and the direct- and magnetically-coupled interconnections for all types of faults and open-circuits are tabulated.The interconnections for any particular dissymmetry can be introduced for faults by the closure, and for open-circuits by the opening, of a switch. The procedure employed is, with the switch (S1) controlling the magnetic interconnections open, to close or open the switch (S2) controlling the direct interconnections, and to determine the current and voltage distributions throughout the network, in particular the voltage across S1. The current or voltage distribution which would be due to the closure of S1 is then determined by an operation equivalent to closing it, i.e. by applying across its terminals a voltage equal and opposite to that determined from the operation of S2. The actual current or voltage distribution for the simultaneous dissymmetries is then the vector sum of the distributions due to the closure (or opening) of S2 and the equivalent closure of S1.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三相系统同步故障的评估
表示三相系统同时不对称的等效电路以前已经处理过,但分析是纯数学的,最终的评估是形式化的。本文采用了更直接的叠加法,因为这样既保留了物理方面,又在总体上减少了计算的工作量;断层的顺序发育也具有间接优势。除同时开路外,分析了两种不对称的所有可能组合。结果已制成表格,便于直接计算。主要操作是将给定系统的对称分量序列网络简化为源和非对称位置之间最简单的阻抗排列。然后,网络相互连接,以便在两个位置都符合序列电流和电压之间的相关约束。一般来说,在一个位置的互连可以直接进行,而在另一个位置则需要磁耦合。所有类型的故障和开路的约束和直接耦合和磁耦合互连被制成表格。对于任何特定不对称的互连都可以通过开关的闭合来引入故障,而对于开路电路则可以通过开关的打开来引入。所采用的程序是,随着开关(S1)控制磁互连的打开,关闭或打开控制直接互连的开关(S2),并确定整个网络中的电流和电压分布,特别是S1上的电压。由于S1闭合而产生的电流或电压分布由相当于关闭S1的操作决定,即通过在其两端施加与S2操作所确定的电压相等且相反的电压来确定。同时不对称的实际电流或电压分布是由于S2闭合(或打开)和S1等效闭合引起的分布的矢量和。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The flash tube and its applications Corrigendum: The predetermination of the magnetic properties of ferromagnetic laminae at power and audio frequencies The authors' replies to the discussion on "Development of locators of small metallic bodies buried in the ground" Development of locators of small metallic bodies buried in the ground Transformer economic efficiency
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1