Stability Assessment of Power System Models For Higher Wind Penetration

T. Geetha, V. Jayashankar
{"title":"Stability Assessment of Power System Models For Higher Wind Penetration","authors":"T. Geetha, V. Jayashankar","doi":"10.1109/ICPST.2008.4745226","DOIUrl":null,"url":null,"abstract":"For grids of low X/R ratios voltage control through active power is effective in reducing the voltage at the point of interconnection of wind farms to grid. Active power voltage control can be achieved using energy storage schemes or inter connectors. In this paper we propose variable frequency transformers (VFT) as an effective means of interconnecting synchronous or asynchronous regions to enhance wind penetration. It is shown that the steady state stability limits of the system are improved with VFT as inter connectors. Also the performance of the VFT under open circuit and short circuit conditions are evaluated.","PeriodicalId":107016,"journal":{"name":"2008 Joint International Conference on Power System Technology and IEEE Power India Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Joint International Conference on Power System Technology and IEEE Power India Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2008.4745226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

For grids of low X/R ratios voltage control through active power is effective in reducing the voltage at the point of interconnection of wind farms to grid. Active power voltage control can be achieved using energy storage schemes or inter connectors. In this paper we propose variable frequency transformers (VFT) as an effective means of interconnecting synchronous or asynchronous regions to enhance wind penetration. It is shown that the steady state stability limits of the system are improved with VFT as inter connectors. Also the performance of the VFT under open circuit and short circuit conditions are evaluated.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
大风侵彻下电力系统模型稳定性评估
对于低X/R比的电网,通过有功功率进行电压控制可以有效地降低风电场与电网互连点的电压。有功电压控制可以通过储能方案或内部连接器来实现。在本文中,我们提出变频变压器(VFT)作为一种有效的手段,互联同步或异步区域,以提高风穿透。结果表明,采用VFT作为互连体,系统的稳态稳定极限得到了提高。并对该系统在开路和短路条件下的性能进行了评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Formulas for Calculating Physical Grounding Resistance of Grounding Wire - Electric Pole System of High Voltage Transmission Lines Torque Ripple Minimization in Direct Torque Control based IM Drive Part-I: Single-rate Control Strategy Power Systems Voltage Stability Using Artificial Neural Network Ranking of Prospective New Generation Location for a Power Network in a Deregulated System Design of Genetic Algorithm Based Fuzzy Logic Power System Stabilizers in Multimachine Power System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1