The vacuum flashover of Dow-Corning type 704 diffusion-pump oil

G. Huttlin, A. Lelis, A. G. Stewart
{"title":"The vacuum flashover of Dow-Corning type 704 diffusion-pump oil","authors":"G. Huttlin, A. Lelis, A. G. Stewart","doi":"10.1109/EIC.1982.7464445","DOIUrl":null,"url":null,"abstract":"Surface flashover characteristics of Dow-Corning type 704 diffusion-pump oil (DC-704) were measured to determine the suitability of this fluid as a vacuum barrier in pulse-power accelerators. These experiments were conducted on an Ion Physics Corporation FX-45 pulse generator, which provided 28-ns (FWHM) pulses in the 500- to 1000-kV range. These pulses went to either a resistive load or a field-emission diode via a vacuum-insulated coaxial transmission line partially filled with the oil. To date, almost 400 pulses have been fired and fields over 200-kV/cm have been sustained. For instances where the oil surface did flash over, open-shutter photographs recorded the spark channels. Since their probability did not show a strong field dependence, we believe that flashovers at these levels were due to spurious phenomena.","PeriodicalId":422317,"journal":{"name":"1982 IEEE International Conference on Electrical Insulation","volume":"264 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1982-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1982 IEEE International Conference on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.1982.7464445","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Surface flashover characteristics of Dow-Corning type 704 diffusion-pump oil (DC-704) were measured to determine the suitability of this fluid as a vacuum barrier in pulse-power accelerators. These experiments were conducted on an Ion Physics Corporation FX-45 pulse generator, which provided 28-ns (FWHM) pulses in the 500- to 1000-kV range. These pulses went to either a resistive load or a field-emission diode via a vacuum-insulated coaxial transmission line partially filled with the oil. To date, almost 400 pulses have been fired and fields over 200-kV/cm have been sustained. For instances where the oil surface did flash over, open-shutter photographs recorded the spark channels. Since their probability did not show a strong field dependence, we believe that flashovers at these levels were due to spurious phenomena.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
道康宁704型扩散泵油的真空闪络
对道康宁704型扩散泵油(DC-704)的表面闪络特性进行了测试,以确定该流体作为脉冲功率加速器真空屏障的适用性。这些实验是在离子物理公司的FX-45脉冲发生器上进行的,该脉冲发生器提供500至1000千伏范围内的28纳秒(FWHM)脉冲。这些脉冲通过部分填充油的真空绝缘同轴传输线进入电阻负载或场发射二极管。迄今为止,已经发射了近400个脉冲,并维持了200千伏/厘米以上的电场。例如,当油表面确实闪过时,打开快门的照片记录了火花通道。由于它们的概率没有表现出很强的场依赖性,我们认为这些水平的闪络是由于虚假现象造成的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impulse corona in positive rod-plane gaps filled with SF6 gas mixtures Polymer concrete as a dielectric material a critical assessment of the state-of-the-art Estimation of cable life and service reliability A prediction of deposition of contaminants on insulator surface with and without grading rings Influence of electrode surface roughness on the impulse breakdown probabilities of SF6
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1