G. Devi, P. Rajesh, S. Sathish, S. Sivaraman, S. Fayaz
{"title":"Performance Investigation of Hexagram Inverter for High Power Applications","authors":"G. Devi, P. Rajesh, S. Sathish, S. Sivaraman, S. Fayaz","doi":"10.1109/ICSCAN.2019.8878797","DOIUrl":null,"url":null,"abstract":"This paper presents the performance investigation of Hexagram Inverter for high power applications. It can be used for 3-phase and 6-phase applications. It has many advantages such as less number of switches, easy construction and maintenance, isolated dc buses. Further, due to the module interconnection it has built-in fault tolerant feature. Compared to cascaded H-bridge inverter, it requires low dc energy storage. This well-known quality makes the system in high power applications. Hexagram inverter fed three phase induction motor drive is developed in Matlab/Simulink environment. Simulation is carried out to study the performance of the 3-phase induction motor at different load conditions and the results are presented.","PeriodicalId":363880,"journal":{"name":"2019 IEEE International Conference on System, Computation, Automation and Networking (ICSCAN)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE International Conference on System, Computation, Automation and Networking (ICSCAN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSCAN.2019.8878797","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
This paper presents the performance investigation of Hexagram Inverter for high power applications. It can be used for 3-phase and 6-phase applications. It has many advantages such as less number of switches, easy construction and maintenance, isolated dc buses. Further, due to the module interconnection it has built-in fault tolerant feature. Compared to cascaded H-bridge inverter, it requires low dc energy storage. This well-known quality makes the system in high power applications. Hexagram inverter fed three phase induction motor drive is developed in Matlab/Simulink environment. Simulation is carried out to study the performance of the 3-phase induction motor at different load conditions and the results are presented.