The Effect of Conventional and Distal Radial Access Techniques on Radial Artery Structure and Vascular Functions

Can Özkan, E. Kızıltunç, V. Cayhan, İ. Yakıcı, M. Çetin, A. Korkmaz, Birsen Doğanay, E. Örnek
{"title":"The Effect of Conventional and Distal Radial Access Techniques on Radial Artery Structure and Vascular Functions","authors":"Can Özkan, E. Kızıltunç, V. Cayhan, İ. Yakıcı, M. Çetin, A. Korkmaz, Birsen Doğanay, E. Örnek","doi":"10.51645/khj.2022.m204","DOIUrl":null,"url":null,"abstract":"Introduction: To compare radial artery (RA) diameters, intima-media thickness (IMT), and vascular functions before and after conventional and distal RA cannulation. It has been proposed that distal transradial (DTRA) cannulation can reduce RA complications. However, there has been no comparative study examining the effects of DTR and conventional transradial (CTRA) intervention on RA structure and function.\n Patients and Methods: Radial artery diameter, IMT, flow-mediated vasodilation (FMD) response were measured using conventional and Doppler RA ultrasonography before, and one day and one month after the procedure in patients who underwent CTRA or DTRA.\n Results: While baseline and first-day IMT values were similar between the groups, first-month IMT values in the CTRA group were found to be significantly increased compared to those in the DTRA group (CTRA= 0.39 ± 0.10 mm, DTRA= 0.32 ± 0.07 mm, p= 0.016). While proximal RA occlusion developed in three patients who underwent CTRA, it did not develop in any of the patients undergoing DTRA (p= 0.072).\n Conclusion: In patients who underwent CTRA, RA IMT increased significantly in the first month after the procedure, compared to patients who underwent DTRA. Proximal RAO was not observed in any of the patients who underwent DTRA.","PeriodicalId":239985,"journal":{"name":"Koşuyolu Heart Journal","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Koşuyolu Heart Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51645/khj.2022.m204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Introduction: To compare radial artery (RA) diameters, intima-media thickness (IMT), and vascular functions before and after conventional and distal RA cannulation. It has been proposed that distal transradial (DTRA) cannulation can reduce RA complications. However, there has been no comparative study examining the effects of DTR and conventional transradial (CTRA) intervention on RA structure and function. Patients and Methods: Radial artery diameter, IMT, flow-mediated vasodilation (FMD) response were measured using conventional and Doppler RA ultrasonography before, and one day and one month after the procedure in patients who underwent CTRA or DTRA. Results: While baseline and first-day IMT values were similar between the groups, first-month IMT values in the CTRA group were found to be significantly increased compared to those in the DTRA group (CTRA= 0.39 ± 0.10 mm, DTRA= 0.32 ± 0.07 mm, p= 0.016). While proximal RA occlusion developed in three patients who underwent CTRA, it did not develop in any of the patients undergoing DTRA (p= 0.072). Conclusion: In patients who underwent CTRA, RA IMT increased significantly in the first month after the procedure, compared to patients who underwent DTRA. Proximal RAO was not observed in any of the patients who underwent DTRA.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
常规和远端桡动脉通路技术对桡动脉结构和血管功能的影响
目的:比较桡动脉(RA)桡动脉(RA)直径、内膜-中膜厚度(IMT)以及桡动脉远端插管前后的血管功能。经桡骨远端插管(DTRA)可以减少RA并发症。然而,目前还没有关于DTR和常规经桡骨(CTRA)干预对RA结构和功能影响的比较研究。患者和方法:在行CTRA或DTRA的患者术前、术后1天和1个月分别采用常规和多普勒RA超声测量桡动脉直径、IMT、血流介导的血管舒张(FMD)反应。结果:两组间基线和第一天IMT值相似,CTRA组第一个月IMT值明显高于DTRA组(CTRA= 0.39±0.10 mm, DTRA= 0.32±0.07 mm, p= 0.016)。三名接受CTRA的患者发生近端RA闭塞,而所有接受DTRA的患者均未发生近端RA闭塞(p= 0.072)。结论:在接受CTRA的患者中,与接受DTRA的患者相比,RA IMT在手术后的第一个月显著增加。在任何接受DTRA的患者中未观察到近端RAO。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Predictive Value of Post-operative Cardiac Troponin I and Lactate Levels After Ventricular Septal Defect Closure Clinical Outcomes and Quality of Life Following TEVAR with or without Revascularization of the Left Subclavian Artery Distal Versus Proximal Radial Intervention; Is It Really Worth of It? What Did the Latest Updated Pulmonary Hypertension Guide Bring? Current Position and Future Perspectives of Melatonin and Its Supplements in Pulmonary Hypertension
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1