Partial discharges in high-voltage transformers

F. A. Sakarya, M. Hayes
{"title":"Partial discharges in high-voltage transformers","authors":"F. A. Sakarya, M. Hayes","doi":"10.1109/SSAP.1992.246887","DOIUrl":null,"url":null,"abstract":"A novel approach to on-line localization of partial discharges in a power transformer is presented. A 2-D technique based on subspace rotation is given. By far-field source and narrowband signal assumptions, the localization problem is reduced to an arrival angle estimation problem. The first step uses two eigenvalue decompositions to clean the data and compute the time delays. The second step converts time delays into source locations using the geometrical relationships between them. The new localization technique computes 2-D arrival angles directly from the normalized eigenvectors of a newly derived signal space matrix. The method eliminates the constraint on subarray spacing and the need for a search procedure inherent in most 2-D eigenanalysis techniques, and does not require pairing of angles.<<ETX>>","PeriodicalId":309407,"journal":{"name":"[1992] IEEE Sixth SP Workshop on Statistical Signal and Array Processing","volume":"11 4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1992] IEEE Sixth SP Workshop on Statistical Signal and Array Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SSAP.1992.246887","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A novel approach to on-line localization of partial discharges in a power transformer is presented. A 2-D technique based on subspace rotation is given. By far-field source and narrowband signal assumptions, the localization problem is reduced to an arrival angle estimation problem. The first step uses two eigenvalue decompositions to clean the data and compute the time delays. The second step converts time delays into source locations using the geometrical relationships between them. The new localization technique computes 2-D arrival angles directly from the normalized eigenvectors of a newly derived signal space matrix. The method eliminates the constraint on subarray spacing and the need for a search procedure inherent in most 2-D eigenanalysis techniques, and does not require pairing of angles.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高压变压器局部放电
提出了一种电力变压器局部放电在线定位的新方法。给出了一种基于子空间旋转的二维方法。通过对远场源和窄带信号的假设,将定位问题简化为到达角估计问题。第一步使用两次特征值分解来清理数据并计算时间延迟。第二步利用时延之间的几何关系将时延转换为源位置。新的定位技术直接从新导出的信号空间矩阵的归一化特征向量计算二维到达角。该方法消除了大多数二维特征分析技术对子阵列间距的限制和搜索过程的需要,并且不需要对角度进行配对。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Linear prediction based on higher order statistics by a new criterion Fourth-order cumulant structure forcing: application to blind array processing Wideband spatial processing with wavelet transforms Simultaneous CFAR detection and frequency estimation of a sinusoidal signal in noise Least-squares reconstruction of an image from its noisy observations using the bispectrum
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1