Wavelength shift analysis techniques & methods for dual mode surface plasmon resonance sensors

M. Florea, J. Hastings, C. Adeola
{"title":"Wavelength shift analysis techniques & methods for dual mode surface plasmon resonance sensors","authors":"M. Florea, J. Hastings, C. Adeola","doi":"10.1109/SECON.2008.4494333","DOIUrl":null,"url":null,"abstract":"The range of detection of surface plasmon resonance (SPR) sensors is limited by the accuracy of wavelength shift detection. In this paper we overview peak shift, centroid, polynomial fit, and raw point methods of mathematical wavelength shift calculation. We also investigate raw data based, integral, and slope based proportional integral derivative (PID) methods of wavelength tracking for temperature tunable laser tracking. Results indicate that polynomial fit is the superior method for mathematical calculation and the PID (slope based) is the preferred method for laser tracking.","PeriodicalId":188817,"journal":{"name":"IEEE SoutheastCon 2008","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE SoutheastCon 2008","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SECON.2008.4494333","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The range of detection of surface plasmon resonance (SPR) sensors is limited by the accuracy of wavelength shift detection. In this paper we overview peak shift, centroid, polynomial fit, and raw point methods of mathematical wavelength shift calculation. We also investigate raw data based, integral, and slope based proportional integral derivative (PID) methods of wavelength tracking for temperature tunable laser tracking. Results indicate that polynomial fit is the superior method for mathematical calculation and the PID (slope based) is the preferred method for laser tracking.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双模表面等离子体共振传感器的波长移分析技术与方法
表面等离子体共振(SPR)传感器的探测范围受限于波长偏移探测的精度。本文综述了峰移法、质心法、多项式拟合法和原始点法的数学波长移计算。我们还研究了基于原始数据、积分和基于斜率的比例积分导数(PID)的波长跟踪方法,用于温度可调激光跟踪。结果表明,多项式拟合是较好的数学计算方法,PID(基于斜率的)是激光跟踪的首选方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Web-based interactive Student Advising system using Java frameworks Development of a nanoscale directionally sensitive optical radiation sensor for guidance and control of nanorobotic space exploration systems -the VCELL SVM for automatic rodent sleep-wake classification Low-frequency amplifiers for PVDF film sensors Dynamics and simulation of a space robot in a gravitational field
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1