Remaining Service Life Struktur Conveyor C pada Tambang Batubara PT XYZ di Kabupaten Kotabaru, Provinsi Kalimantan Selatan

M. Ikbal, Elfida Moralista, N. F. Isniarno
{"title":"Remaining Service Life Struktur Conveyor C pada Tambang Batubara PT XYZ di Kabupaten Kotabaru, Provinsi Kalimantan Selatan","authors":"M. Ikbal, Elfida Moralista, N. F. Isniarno","doi":"10.29313/bcsme.v2i2.3402","DOIUrl":null,"url":null,"abstract":"Abstract. The structure of the conveyor is made of steel which is subject to corrosion. The disadvantage of corrosion is that it results in a reduction in the thickness of the conveyor structure. Therefore, it is necessary to control and monitor corrosion on the conveyor structure to be observed, so that corrosion can be controlled. The purpose of this research is to determine the type of corrosion, corrosion rate, remaining service life, and control methods. The methodology used in this study is measuring the thickness reduction of the conveyor structure. This research was conducted on a conveyor structure of 90 meters above ground level. Measurement of the thickness of the conveyor structure using the Ultrasonic Thickness Gauge TT 130 at 25 observation points. The environmental conditions in the research area are the air temperature in the range of 25,8 oC-27,9oC, while the rainfall with an average range of 9.2 mm-479.2 mm. The type of corrosion that occurs in the conveyor structure is uniform corrosion. In controlling this corrosion using a coating method with Seaguard 5000 primer coating, Sherglass FF intermediate coating, and aliphatic acrylic modified polyurethane top coating. The corrosion rate of the conveyor structure ranges from 0.1733-0.3000 mm/year which is included in the good category based on the relative corrosion resistance of steel. Meanwhile, the remaining service life of the conveyor structure ranges from 8.10- 11.43 years. The service life of the conveyor structure is 6 years, while the design life is 15 years. Based on the calculation of the remaining service life of the conveyor structure at 25 observation points, the percentage of 36.00% is predicted to be below the design life. \nAbstrak. Struktur conveyor terbuat dari baja yang dapat mengalami korosi. Kerugian terjadinya korosi yaitu mengakibatkan pengurangan ketebalan struktur conveyor. Oleh karena itu, diperlukannya pengendalian serta monitoring korosi pada struktur conveyor yang akan diamati, sehingga korosi dapat dikendalikan. Tujuan dilakukannya penelitian ini adalah untuk mengetahui jenis korosi, laju korosi, sisa umur pakai, dan metoda pengendaliannya. Metodologi yang digunakan dalam penelitian ini yaitu pengukuran pengurangan ketebalan struktur conveyor. Penelitian ini dilakukan pada struktur conveyor sepanjang 90 meter yang berada di atas permukaan tanah. Pengukuran ketebalan struktur conveyor menggunakan alat Ultrasonic Thickness Gauge TT 130 pada 25 test point. Kondisi lingkungan di daerah penelitian yaitu temperatur udara kisaran 25,8 oC-27,9oC, sedangkan curah hujan dengan rata-rata kisaran 9,2 mm-479,2 mm. Jenis korosi yang terjadi pada struktur conveyor adalah korosi merata. Dalam pengendalian korosi ini menggunakan metoda coating dengan primer coating Seaguard 5000, intermediate coating Sherglass FF, dan top coating aliphatic acrylic modified polyurethane. Laju korosi struktur conveyor berkisar antara 0,1733-0,3000 mm/tahun termasuk ke dalam kategori good berdasarkan ketahanan korosi relatif baja. Sedangkan sisa umur pakai struktur conveyor berkisar antara 8,10-11,43 tahun. Umur pakai struktur conveyor yaitu 6 tahun, sedangkan umur desainnya 15 tahun. Berdasarkan dari hasil perhitungan sisa umur pakai struktur conveyor pada 25 test point, didapatkan persentase sebesar 36,00% yang diprediksi di bawah umur desainnya.","PeriodicalId":187584,"journal":{"name":"Bandung Conference Series: Mining Engineering","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bandung Conference Series: Mining Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29313/bcsme.v2i2.3402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract. The structure of the conveyor is made of steel which is subject to corrosion. The disadvantage of corrosion is that it results in a reduction in the thickness of the conveyor structure. Therefore, it is necessary to control and monitor corrosion on the conveyor structure to be observed, so that corrosion can be controlled. The purpose of this research is to determine the type of corrosion, corrosion rate, remaining service life, and control methods. The methodology used in this study is measuring the thickness reduction of the conveyor structure. This research was conducted on a conveyor structure of 90 meters above ground level. Measurement of the thickness of the conveyor structure using the Ultrasonic Thickness Gauge TT 130 at 25 observation points. The environmental conditions in the research area are the air temperature in the range of 25,8 oC-27,9oC, while the rainfall with an average range of 9.2 mm-479.2 mm. The type of corrosion that occurs in the conveyor structure is uniform corrosion. In controlling this corrosion using a coating method with Seaguard 5000 primer coating, Sherglass FF intermediate coating, and aliphatic acrylic modified polyurethane top coating. The corrosion rate of the conveyor structure ranges from 0.1733-0.3000 mm/year which is included in the good category based on the relative corrosion resistance of steel. Meanwhile, the remaining service life of the conveyor structure ranges from 8.10- 11.43 years. The service life of the conveyor structure is 6 years, while the design life is 15 years. Based on the calculation of the remaining service life of the conveyor structure at 25 observation points, the percentage of 36.00% is predicted to be below the design life. Abstrak. Struktur conveyor terbuat dari baja yang dapat mengalami korosi. Kerugian terjadinya korosi yaitu mengakibatkan pengurangan ketebalan struktur conveyor. Oleh karena itu, diperlukannya pengendalian serta monitoring korosi pada struktur conveyor yang akan diamati, sehingga korosi dapat dikendalikan. Tujuan dilakukannya penelitian ini adalah untuk mengetahui jenis korosi, laju korosi, sisa umur pakai, dan metoda pengendaliannya. Metodologi yang digunakan dalam penelitian ini yaitu pengukuran pengurangan ketebalan struktur conveyor. Penelitian ini dilakukan pada struktur conveyor sepanjang 90 meter yang berada di atas permukaan tanah. Pengukuran ketebalan struktur conveyor menggunakan alat Ultrasonic Thickness Gauge TT 130 pada 25 test point. Kondisi lingkungan di daerah penelitian yaitu temperatur udara kisaran 25,8 oC-27,9oC, sedangkan curah hujan dengan rata-rata kisaran 9,2 mm-479,2 mm. Jenis korosi yang terjadi pada struktur conveyor adalah korosi merata. Dalam pengendalian korosi ini menggunakan metoda coating dengan primer coating Seaguard 5000, intermediate coating Sherglass FF, dan top coating aliphatic acrylic modified polyurethane. Laju korosi struktur conveyor berkisar antara 0,1733-0,3000 mm/tahun termasuk ke dalam kategori good berdasarkan ketahanan korosi relatif baja. Sedangkan sisa umur pakai struktur conveyor berkisar antara 8,10-11,43 tahun. Umur pakai struktur conveyor yaitu 6 tahun, sedangkan umur desainnya 15 tahun. Berdasarkan dari hasil perhitungan sisa umur pakai struktur conveyor pada 25 test point, didapatkan persentase sebesar 36,00% yang diprediksi di bawah umur desainnya.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
摘要。输送机的结构由易腐蚀的钢材制成。腐蚀的缺点是它会导致输送机结构厚度的减少。因此,有必要对待观察输送机结构上的腐蚀进行控制和监测,以便对腐蚀进行控制。本研究的目的是确定腐蚀类型、腐蚀速率、剩余使用寿命和控制方法。在这项研究中使用的方法是测量厚度减少的输送机结构。本研究是在距地面90米的输送机结构上进行的。采用超声波测厚仪TT 130在25个观测点测量输送机结构厚度。研究区环境条件为气温25.8℃~ 27.9℃,平均降雨量9.2 mm ~ 479.2 mm。输送机结构中发生的腐蚀类型为均匀腐蚀。采用Seaguard 5000底漆、Sherglass FF中间漆和脂肪族丙烯酸改性聚氨酯面漆的涂覆方法来控制这种腐蚀。输送机结构腐蚀速率为0.1733-0.3000 mm/年,根据钢材的相对耐腐蚀性,属于良好类别。同时,输送机结构的剩余使用寿命为8.10 ~ 11.43年。输送机结构使用寿命为6年,设计寿命为15年。通过对25个观测点输送机结构剩余使用寿命的计算,预测其低于设计寿命的比例为36.00%。Abstrak。Struktur传送带terbuat dari baja yang dapat mengalami korosi。Kerugian terjadinya korosi yitu mengakibatkan pengurangan ketebalan结构输送机。Oleh karena itu, diperlukannya pengendalian serta监测korosi patat结构输送机yang akan diamati, sehinga korosi patat dikendalikan。Tujuan dilakukannya penelitian ini adalah untuk mengetahui jenis korosi, laju korosi, sisa umur pakai, dan metoda pengendaliannya。方法学杨迪古那坎dalam penelitian ini yitu企鹅kuran pengurangan ketebalan构造输送机。Penelitian ini dilakukan pada结构输送机sepanjang 90米yang berada di数据permukaan tanah。企鹅ketebalan罢工输送机蒙古那坎alat超声波测厚仪TT 130帕达25测试点。Kondisi lingkungan di daerah penelitian yitu temperature udara kisaran 25,8℃-27,9℃,sedangkan curah hujan dengan rata-rata kisaran 9,2 mm-479,2 mm。Jenis korosi yang terjadi pada结构输送机adalah korosi merata。大连大连科罗西尼蒙古纳坎中土涂料丹安底漆Seaguard 5000,中间涂料Sherglass FF,丹面涂料脂族丙烯酸改性聚氨酯。拉ju korosi结构输送机berkisar antara 0,1733-0,3000 mm/tahun termasuk ke dalam kategori良好的berdasarkan ketahanan korosi相对baja。西安交通大学学报(自然科学版)8,10-11,43。乌木尔pakai结构输送机yyitu 6塔hun, sedangkan乌木尔desainnya 15塔hun。Berdasarkan dari hasil perhitungan sisa umur pakai结构输送机pad25测试点,didapatkan代表sebesar 3600% yang diprediksi di bawah umur desainnya。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Kajian Kelayakan Ekonomi pada Kegiatan Hauling Tambang Tanah Liat PT Indocement Tunggal Prakarsa TBK Blok Pabuaran di Kecamatan Sukamakmur Kabupaten Bogor Provinsi Jawa Barat Analisis Investasi dan Kelayakan Ekonomi pada Penambangan Sirtu CV Billiant Ningrat di Kecamatan Leles Kabupaten Garut Provinsi Jawa Barat Manajemen Stockpile untuk Mencegah Terjadinya Self-Combustion di PLTU Banten 2 Labuan OMU Monitoring Korosi Discharge Conveyor F pada Tambang Batubara PT XYZ di Kabupaten Merangin Provinsi Jambi Pengaruh Bidang Diskontinu Terhadap Potensi Longsoran Baji pada Lereng Tambang Terbuka di PT Indocement Tunggal Prakarsa Desa Palimanan, Kecamatan Gempol, Kabupaten Cirebon, Provinsi Jawa Barat
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1