Use of virtual Frisch-grid CdZnTe detectors to attain sub-millimeter spatial resolution

Kisung Lee, A. Bolotnikov, Seungbin Bae, U. Roy, G. Camarda, M. Petryk, Yonggang Cui, A. Hossain, Ge Yang, V. Dedic, Kihyun Kim, R. James
{"title":"Use of virtual Frisch-grid CdZnTe detectors to attain sub-millimeter spatial resolution","authors":"Kisung Lee, A. Bolotnikov, Seungbin Bae, U. Roy, G. Camarda, M. Petryk, Yonggang Cui, A. Hossain, Ge Yang, V. Dedic, Kihyun Kim, R. James","doi":"10.1109/NSSMIC.2013.6829830","DOIUrl":null,"url":null,"abstract":"The goal of our study was twofold: To determine the distribution of signals in position-sensitive CdZnTe (CZT)-based virtual Frisch-grid detectors (VFGDs) with side-sensing pads, and to evaluate the feasibility of accurately measuring the X- and Y-coordinates where a photon interaction occurs within a single VFGD module. Accordingly, we collected signals from an anode, and from four or eight sensing pads attached to four sides of a CZT crystal. We assessed the anode's energy spectra and derived histograms from the side electrodes so to evaluate the feasibility of employing VFGDs as imaging devices. Using a highly collimated 30-keV X-ray beam at the National Synchrotron Light Source (NSLS), and applying some corrections to the raw signal data, we found that the signals acquired from one side of the detector were well separated from those measured at the opposite side. We also determined the photon interaction points by conventional Anger logic and via a more sophisticated statistics-based positioning (SBP) algorithm. With the current VFGD configuration, preliminary results showed that our positioning methods could increase the resolution above the intrinsic resolution of the VFGD (6 mm). Using SBP, we achieved a resolution below 1 millimeter for low-energy X- and gamma-rays.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2013.6829830","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The goal of our study was twofold: To determine the distribution of signals in position-sensitive CdZnTe (CZT)-based virtual Frisch-grid detectors (VFGDs) with side-sensing pads, and to evaluate the feasibility of accurately measuring the X- and Y-coordinates where a photon interaction occurs within a single VFGD module. Accordingly, we collected signals from an anode, and from four or eight sensing pads attached to four sides of a CZT crystal. We assessed the anode's energy spectra and derived histograms from the side electrodes so to evaluate the feasibility of employing VFGDs as imaging devices. Using a highly collimated 30-keV X-ray beam at the National Synchrotron Light Source (NSLS), and applying some corrections to the raw signal data, we found that the signals acquired from one side of the detector were well separated from those measured at the opposite side. We also determined the photon interaction points by conventional Anger logic and via a more sophisticated statistics-based positioning (SBP) algorithm. With the current VFGD configuration, preliminary results showed that our positioning methods could increase the resolution above the intrinsic resolution of the VFGD (6 mm). Using SBP, we achieved a resolution below 1 millimeter for low-energy X- and gamma-rays.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用虚拟Frisch-grid CdZnTe探测器获得亚毫米空间分辨率
我们的研究目标是双重的:确定具有侧感垫的基于位置敏感CdZnTe (CZT)的虚拟飞盘网格探测器(VFGD)中的信号分布,并评估在单个VFGD模块中精确测量光子相互作用发生的X和y坐标的可行性。因此,我们从一个阳极和附着在CZT晶体四面的四个或八个传感板收集信号。我们评估了阳极的能谱,并从侧电极导出了直方图,以评估使用VFGDs作为成像设备的可行性。在国家同步加速器光源(NSLS)使用高度准直的30 kev x射线束,并对原始信号数据进行一些校正,我们发现从探测器一侧获得的信号与在另一侧测量的信号分离得很好。我们还通过传统的Anger逻辑和更复杂的基于统计的定位(SBP)算法确定了光子相互作用点。在目前的VFGD配置下,初步结果表明,我们的定位方法可以将VFGD的固有分辨率(6 mm)提高到以上。使用SBP,我们实现了低能量X射线和伽马射线低于1毫米的分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Scientific Trigger Unit for space-based real-time gamma ray burst detection I - Scientific software model and simulations Study on two-cell rf-deflector cavity for ultra-short electron bunch measurement Applications of many-core technologies to on-line event reconstruction in High Energy Physics experiments Optimization of the gas system in the CMS RPC detector at the LHC Performance of the ATLAS calorimeter trigger in the LHC Run 1 data taking period
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1