Accurate measurement of natural gas consumption: the economic impact on power generation operations

W.J. Astlesford, S. R. Johnson
{"title":"Accurate measurement of natural gas consumption: the economic impact on power generation operations","authors":"W.J. Astlesford, S. R. Johnson","doi":"10.1109/IECEC.1997.656675","DOIUrl":null,"url":null,"abstract":"Deregulation of electricity under FERC Order 888 will result in open access for consumers and competition among suppliers. The method of measuring natural gas transfers is normally specified in the contract between the buyer and the seller. Monthly billings are based on a custody transfer flow meter, which is usually owned and maintained by the transporter. An inaccurate custody transfer meter can be a detriment to either the buyer or the transporter of the gas, depending on whether the meter over- or under-registers the volume of gas involved in the transaction. For this reason, most commercial gas buyers monitor the gas exchange with an in-plant check meter or compare to inplant meters used on process equipment to help ensure that both the buyer and seller are treated fairly and equitably. This paper presents a case study in which the buyer, Nevada Cogeneration Associates (NCA), and the transporter, Southwest Gas Corporation (SWG), agreed to a recalibration of a custody transfer turbine meter and the attached pressure/temperature corrector. The meter and corrector were sent to the Gas Research Institute (GRI) Metering Research Facility (MRF) located at Southwest Research Institute (SwRI) in San Antonio, Texas. The custody transfer meter was calibrated (proven) against critical flow venturi reference flowmeters that are accurate to a nominal 10.2%. Following calibration of the meter and evaluation of the corrector, it was found that the combination had overregistered the volume of gas by an average of about 1.088% of reading.","PeriodicalId":183668,"journal":{"name":"IECEC-97 Proceedings of the Thirty-Second Intersociety Energy Conversion Engineering Conference (Cat. No.97CH6203)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECEC-97 Proceedings of the Thirty-Second Intersociety Energy Conversion Engineering Conference (Cat. No.97CH6203)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECEC.1997.656675","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Deregulation of electricity under FERC Order 888 will result in open access for consumers and competition among suppliers. The method of measuring natural gas transfers is normally specified in the contract between the buyer and the seller. Monthly billings are based on a custody transfer flow meter, which is usually owned and maintained by the transporter. An inaccurate custody transfer meter can be a detriment to either the buyer or the transporter of the gas, depending on whether the meter over- or under-registers the volume of gas involved in the transaction. For this reason, most commercial gas buyers monitor the gas exchange with an in-plant check meter or compare to inplant meters used on process equipment to help ensure that both the buyer and seller are treated fairly and equitably. This paper presents a case study in which the buyer, Nevada Cogeneration Associates (NCA), and the transporter, Southwest Gas Corporation (SWG), agreed to a recalibration of a custody transfer turbine meter and the attached pressure/temperature corrector. The meter and corrector were sent to the Gas Research Institute (GRI) Metering Research Facility (MRF) located at Southwest Research Institute (SwRI) in San Antonio, Texas. The custody transfer meter was calibrated (proven) against critical flow venturi reference flowmeters that are accurate to a nominal 10.2%. Following calibration of the meter and evaluation of the corrector, it was found that the combination had overregistered the volume of gas by an average of about 1.088% of reading.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
准确计量天然气消耗量:对发电运行的经济影响
根据联邦能源监管委员会第888号命令,放松对电力的管制将导致消费者的开放获取和供应商之间的竞争。衡量天然气转让的方法通常在买方和卖方之间的合同中规定。每月的账单是根据保管转移流量计计算的,该流量计通常由运输商拥有和维护。不准确的保管转移仪表可能对天然气的买方或运输商造成损害,这取决于仪表是否过高或过低地记录了交易中涉及的天然气量。出于这个原因,大多数商业天然气买家都使用工厂内检查仪表来监控气体交换,或者与过程设备上使用的工厂内仪表进行比较,以帮助确保买卖双方都得到公平和公正的对待。本文介绍了一个案例研究,其中买方内华达热电联产公司(NCA)和运输商西南天然气公司(SWG)同意重新校准托管转移涡轮仪表和附加的压力/温度校正器。仪表和校正器被送到位于德克萨斯州圣安东尼奥西南研究所(SwRI)的天然气研究所(GRI)计量研究设施(MRF)。监护传输仪表是针对临界流量文丘里参考流量计校准的(经过验证),精确到标称的10.2%。在对仪表进行校正和对校正器进行评估后,发现该组合将气体体积平均高估了读数的1.088%左右。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Electrical characterization testing of sealed nickel-zinc batteries Characteristics of energy savings in an ideal heat-integrated distillation column (HIDiC) PX series AMTEC cell design, testing, and analysis The effect of 'flushing ratio' on the performance of counterflow fixed-bed thermal regenerators [for Stirling cycle machines] Effect of design variations on AMTEC cell efficiency, and of operating parameters on performance of OSC cell design
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1