Nonlinear methods of analysis to examine respiratory waveform variability during oral feeding in preterm infants

Caryn Bradley, Phyllis Guarrera-Bowlby, H. Damodaran, Michael Ballintyn, J. Hagadorn
{"title":"Nonlinear methods of analysis to examine respiratory waveform variability during oral feeding in preterm infants","authors":"Caryn Bradley, Phyllis Guarrera-Bowlby, H. Damodaran, Michael Ballintyn, J. Hagadorn","doi":"10.1504/IJMEI.2017.10004455","DOIUrl":null,"url":null,"abstract":"In a novel exploratory study, nonlinear methods of analysis for respiratory patterns were used to examine respiratory waveform variability during oral feeding in preterm infants. Twelve healthy preterm infants were studied using a within-subject cross over design to compare semi-upright and the elevated sidelying position during bottle feeding. Outcome measures were physiologic indicators of cardiopulmonary status: heart rate, respiratory rate, oxygen saturation and respiratory pattern variability. Preliminary results suggest that analysis of respiratory waveform variability is feasible and may be a more sensitive measure of cardiopulmonary physiology than means for heart rate, respiratory rate and percent haemoglobin oxygen saturation. Nonlinear methods of analysis of the respiratory data provide a distinct perspective on the adaptability of infants' breathing patterns while feeding. The clinical application of monitoring respiratory waveforms using nonlinear methods may be helpful in identifying readiness to initiate and advance feeds orally in preterm infants.","PeriodicalId":193362,"journal":{"name":"Int. J. Medical Eng. Informatics","volume":"272 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Int. J. Medical Eng. Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJMEI.2017.10004455","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In a novel exploratory study, nonlinear methods of analysis for respiratory patterns were used to examine respiratory waveform variability during oral feeding in preterm infants. Twelve healthy preterm infants were studied using a within-subject cross over design to compare semi-upright and the elevated sidelying position during bottle feeding. Outcome measures were physiologic indicators of cardiopulmonary status: heart rate, respiratory rate, oxygen saturation and respiratory pattern variability. Preliminary results suggest that analysis of respiratory waveform variability is feasible and may be a more sensitive measure of cardiopulmonary physiology than means for heart rate, respiratory rate and percent haemoglobin oxygen saturation. Nonlinear methods of analysis of the respiratory data provide a distinct perspective on the adaptability of infants' breathing patterns while feeding. The clinical application of monitoring respiratory waveforms using nonlinear methods may be helpful in identifying readiness to initiate and advance feeds orally in preterm infants.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
研究早产儿口服喂养时呼吸波形变异性的非线性分析方法
在一项新的探索性研究中,使用非线性呼吸模式分析方法来检查早产儿口服喂养期间呼吸波形的变异性。采用受试者内交叉设计对12名健康早产儿进行了研究,以比较奶瓶喂养时的半直立姿势和抬高侧卧姿势。结果测量是心肺状态的生理指标:心率、呼吸频率、氧饱和度和呼吸模式变异性。初步结果表明,分析呼吸波形变异性是可行的,可能是比心率、呼吸频率和血红蛋白氧饱和度百分比更敏感的心肺生理学指标。呼吸数据的非线性分析方法提供了婴儿在喂养时呼吸模式适应性的独特视角。使用非线性方法监测呼吸波形的临床应用可能有助于识别早产儿是否准备开始和提前口服喂养。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Computational fluid dynamics analysis of carotid artery with different plaque shapes Pilot study of THz metamaterial-based biosensor for pharmacogenetic screening Access control to the electronic health records: a case study of an Algerian health organisation The impact of income level on childhood asthma in the USA: a secondary analysis study during 2011-2012 A low-complexity volumetric model with dynamic inter-connections to represent human liver in surgical simulators
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1