Voltage source converter connected to very weak grids under disturbances

M. Arani, Y. Mohamed
{"title":"Voltage source converter connected to very weak grids under disturbances","authors":"M. Arani, Y. Mohamed","doi":"10.1109/ISGT.2017.8085987","DOIUrl":null,"url":null,"abstract":"High Voltage Direct Current (HVDC) transmission lines are increasing rapidly and Voltage Source Converter (VSC)-based is one of the most famous types used in the industry. Despites all of its merits, VSCs have not been favored in very weak grids because of stability issues. Recently, these issues have generated much attention in literature and different solutions are proposed. Among the discussed solutions, the artificial bus is one of the most straight-forward and effective methods, which enable VSC to inject or absorb its maximum nominal power. However, this method is not examined under grid disturbances. This paper studies the impact of severe faults, phase jump and frequency changes and discusses the inherent robustness of the method to fill a serious gap in the literature.","PeriodicalId":296398,"journal":{"name":"2017 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT)","volume":"172 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT.2017.8085987","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

High Voltage Direct Current (HVDC) transmission lines are increasing rapidly and Voltage Source Converter (VSC)-based is one of the most famous types used in the industry. Despites all of its merits, VSCs have not been favored in very weak grids because of stability issues. Recently, these issues have generated much attention in literature and different solutions are proposed. Among the discussed solutions, the artificial bus is one of the most straight-forward and effective methods, which enable VSC to inject or absorb its maximum nominal power. However, this method is not examined under grid disturbances. This paper studies the impact of severe faults, phase jump and frequency changes and discusses the inherent robustness of the method to fill a serious gap in the literature.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电压源变换器在干扰下连接到非常弱的电网
高压直流(HVDC)输电线路正在迅速增加,基于电压源变换器(VSC)的输电线路是工业上最著名的输电线路之一。尽管有很多优点,但由于稳定性问题,vsc在非常弱的电网中并不受欢迎。最近,这些问题在文献中引起了很大的关注,并提出了不同的解决方案。在讨论的解决方案中,人工母线是最直接有效的方法之一,它使VSC能够注入或吸收其最大标称功率。然而,该方法没有在网格扰动下进行检验。本文研究了严重故障、相位跳变和频率变化的影响,并讨论了该方法的固有鲁棒性,填补了文献中的严重空白。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A cyber-physical resilience metric for smart grids Optimal allocation of photovoltaic systems and energy storage systems considering constraints of both transmission and distribution systems Stochastic dynamic power flow analysis based on stochastic response surfarce method and ARMA-GARCH model Towards the improvement of multi-objective evolutionary algorithms for service restoration Multi-level control framework for enhanced flexibility of active distribution network
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1