[Radioimmunoanalysis of plasma testosterone].

Revista iberica de endocrinologia Pub Date : 1975-01-01
J A Tresguerres, M D Fernández, M C Fernández-Galaz, A Oriol Bosch
{"title":"[Radioimmunoanalysis of plasma testosterone].","authors":"J A Tresguerres,&nbsp;M D Fernández,&nbsp;M C Fernández-Galaz,&nbsp;A Oriol Bosch","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A simple radioimmunoassay procedure for the determination of testosterone concentration in plasma is described. Small amounts of plasma, 0,5 ml for males and 1 ml for females, are extracted with diethyl ether. Recoveries for the extraction are obtained by the addition of labelled tesosterone. The radioimmunoassay is performed directly on the extracts without further purification. Separation of the free from the antibodie bound testosterone is achieved with dextran coated charocoal. Under the used conditions, the calibration curve covers a range between 0,5 and 1,5 ng per sample. Reproducibility is acceptable with a coefficient of variation of 7%. The normal values are slightly higher than those obtained with methods using some purification step of the extract before the assay but due to its simplicity the described method is a suitable one for clinical purposes.</p>","PeriodicalId":76462,"journal":{"name":"Revista iberica de endocrinologia","volume":"22 127","pages":"23-41"},"PeriodicalIF":0.0000,"publicationDate":"1975-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista iberica de endocrinologia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A simple radioimmunoassay procedure for the determination of testosterone concentration in plasma is described. Small amounts of plasma, 0,5 ml for males and 1 ml for females, are extracted with diethyl ether. Recoveries for the extraction are obtained by the addition of labelled tesosterone. The radioimmunoassay is performed directly on the extracts without further purification. Separation of the free from the antibodie bound testosterone is achieved with dextran coated charocoal. Under the used conditions, the calibration curve covers a range between 0,5 and 1,5 ng per sample. Reproducibility is acceptable with a coefficient of variation of 7%. The normal values are slightly higher than those obtained with methods using some purification step of the extract before the assay but due to its simplicity the described method is a suitable one for clinical purposes.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血浆睾酮放射免疫分析。
本文描述了一种测定血浆中睾酮浓度的简单放射免疫测定方法。用乙醚提取少量血浆,男性0.5 ml,女性1 ml。提取回收率是通过添加标记的睾酮获得的。放射免疫测定直接对提取物进行,无需进一步纯化。游离睾酮与抗体结合睾酮的分离是用葡聚糖包被炭实现的。在所使用的条件下,校准曲线覆盖每个样品0,5至1.5 ng的范围。变异系数为7%,重现性可接受。正常值略高于在测定前使用提取物的某些纯化步骤获得的值,但由于其简单性,所描述的方法适用于临床目的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Study of TRH in the postganglionic sypnasis of the isolated human vas deferens]. [Changes of calcium-phosphorus metabolism in patients with chronic renal failure on hemodialysis treatment]. [Hematin treatment of porphyric neuropathy]. [Clinical trial with a nonamphetaminic anoretic]. [Gynecomastia and marihuana].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1