Assessment of power system transient stability using shunt FACTS devices: SVC and TCBR

S. Messalti, A. Gherbi, S. Belkhiat
{"title":"Assessment of power system transient stability using shunt FACTS devices: SVC and TCBR","authors":"S. Messalti, A. Gherbi, S. Belkhiat","doi":"10.1109/CISTEM.2014.7077014","DOIUrl":null,"url":null,"abstract":"This paper presents comparative study for power system transient stability improvement using Static Var Compensator (SVC) and Thyristor Control Breaking Resistor (TCBR). To show the effectiveness of the dynamic oscillation, relative rotor angles criterion is used for power system transient stability assessment. The proposed method is tested on the WSCC3 nine-bus system in the case of three-phase short circuit fault in one transmission line. Simulation results and comparative study comparison are presented in this paper.","PeriodicalId":115632,"journal":{"name":"2014 International Conference on Electrical Sciences and Technologies in Maghreb (CISTEM)","volume":"149 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Electrical Sciences and Technologies in Maghreb (CISTEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CISTEM.2014.7077014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents comparative study for power system transient stability improvement using Static Var Compensator (SVC) and Thyristor Control Breaking Resistor (TCBR). To show the effectiveness of the dynamic oscillation, relative rotor angles criterion is used for power system transient stability assessment. The proposed method is tested on the WSCC3 nine-bus system in the case of three-phase short circuit fault in one transmission line. Simulation results and comparative study comparison are presented in this paper.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用并联FACTS装置评估电力系统暂态稳定性:SVC和TCBR
本文对静态无功补偿器(SVC)和晶闸管控制破断电阻(TCBR)改善电力系统暂态稳定性进行了比较研究。为了证明动态振荡的有效性,将转子相对角准则用于电力系统暂态稳定评估。在WSCC3九母线系统上进行了单相输电线路三相短路故障的测试。本文给出了仿真结果和对比研究对比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Adaptive hysteresis controller for the Switched Reluctance Machines Critical current density determination of superconducting material Induction machine finite element model for field-oriented control in Electric vehicle power train Solar radiation forecasting using artificial neural network for local power reserve Modeling of a radial flux PM rotating machine using a new hybrid analytical model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1