{"title":"A hysteresis loop control method for output current of three-phase photovoltaic grid-connected inverters","authors":"Bin Wang, Ying Shi, Xin Gao","doi":"10.1145/3548608.3561132","DOIUrl":null,"url":null,"abstract":"In the design of a three-phase photovoltaic grid-connected inverter system, the control strategy usually adopts hysteresis loop current control. To solve this problem, space vector-asymmetric double hysteresisloop current control method is introduced, which can reduce the switching frequency and the switching loss to a certain extent and realize the grid-connected current power factor close to 1. The simulation models based on the three-phase stationary coordinate system and two-phase stationary coordinate system are built-in Matlab/Simulink simulation platform respectively. The two control strategies are compared and analyzed in terms of grid-connected current and voltage, switching frequency, power factor, etc. The simulation results verify the correctness of the control scheme.","PeriodicalId":201434,"journal":{"name":"Proceedings of the 2022 2nd International Conference on Control and Intelligent Robotics","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2022 2nd International Conference on Control and Intelligent Robotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3548608.3561132","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In the design of a three-phase photovoltaic grid-connected inverter system, the control strategy usually adopts hysteresis loop current control. To solve this problem, space vector-asymmetric double hysteresisloop current control method is introduced, which can reduce the switching frequency and the switching loss to a certain extent and realize the grid-connected current power factor close to 1. The simulation models based on the three-phase stationary coordinate system and two-phase stationary coordinate system are built-in Matlab/Simulink simulation platform respectively. The two control strategies are compared and analyzed in terms of grid-connected current and voltage, switching frequency, power factor, etc. The simulation results verify the correctness of the control scheme.