{"title":"Balancing of four wire loads using linearized H-bridge static synchronous compensators","authors":"Abdulkareem Mokif Obais, Ali Abdulkareem Mukheef","doi":"10.11591/ijres.v12.i3.pp462-477","DOIUrl":null,"url":null,"abstract":"In this paper, a load balancing system is designed to balance the secondary phase currents of 11 kV/380 V, 50 Hz, 100 kVA power transformer in a three phase 4-wire, distribution network. The load balancing system is built of six identical modified static synchronous compensators (M-STATCOMs). Each M-STATCOM is constructed of a voltage source converter-based H-bridge controlled in capacitive and inductive modes as a linear compensating susceptance. The M-STATCOM current is controlled by varying its angle such that it exchanges pure reactive current with the utility grid. Three identical M-STATCOMs are connected in delta-form to balance the active phase currents of the power transformer, whereas the other three identical M-STATCOMs are connected in star-form to compensate for reactive currents. The M-STATCOMs in the delta-connected compensator are driven by 380 V line-to-line voltages, whilst, those connected in star-form are driven by 220 V phase voltages. The results of the 220 V and 380 V M-STATCOMs have exhibited linear and continuous control in capacitive and inductive regions of operation without steady-state harmonics. The proposed load balancing system has offered high flexibility during treating moderate and severe load unbalance conditions. It can involve any load unbalance within the power transformer current rating and even unbalance cases beyond the power transformer current rating.","PeriodicalId":158991,"journal":{"name":"International Journal of Reconfigurable and Embedded Systems (IJRES)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Reconfigurable and Embedded Systems (IJRES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/ijres.v12.i3.pp462-477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, a load balancing system is designed to balance the secondary phase currents of 11 kV/380 V, 50 Hz, 100 kVA power transformer in a three phase 4-wire, distribution network. The load balancing system is built of six identical modified static synchronous compensators (M-STATCOMs). Each M-STATCOM is constructed of a voltage source converter-based H-bridge controlled in capacitive and inductive modes as a linear compensating susceptance. The M-STATCOM current is controlled by varying its angle such that it exchanges pure reactive current with the utility grid. Three identical M-STATCOMs are connected in delta-form to balance the active phase currents of the power transformer, whereas the other three identical M-STATCOMs are connected in star-form to compensate for reactive currents. The M-STATCOMs in the delta-connected compensator are driven by 380 V line-to-line voltages, whilst, those connected in star-form are driven by 220 V phase voltages. The results of the 220 V and 380 V M-STATCOMs have exhibited linear and continuous control in capacitive and inductive regions of operation without steady-state harmonics. The proposed load balancing system has offered high flexibility during treating moderate and severe load unbalance conditions. It can involve any load unbalance within the power transformer current rating and even unbalance cases beyond the power transformer current rating.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用线性化h桥静态同步补偿器平衡四线负载
本文设计了一种负载平衡系统,用于平衡三相四线制配电网中11 kV/380 V, 50 Hz, 100 kVA电力变压器的二次电流。负载平衡系统由六个相同的改进静态同步补偿器(M-STATCOMs)组成。每个M-STATCOM都由一个基于电压源变换器的h桥构成,以电容和电感模式控制作为线性补偿电纳。M-STATCOM电流是通过改变其角度来控制的,这样它就可以与公用电网交换纯无功电流。三个相同的m - statcom以三角形连接以平衡电力变压器的有源相电流,而其他三个相同的m - statcom以星形连接以补偿无功电流。三角形连接补偿器中的m - statcom由380 V线对线电压驱动,而星形连接的m - statcom由220 V相电压驱动。结果表明,220v和380v M-STATCOMs在无稳态谐波的电容区和电感区均表现出线性和连续控制。所提出的负载平衡系统在处理中度和重度负载不平衡情况时具有很高的灵活性。它可以涉及在电力变压器额定电流范围内的任何负载不平衡,甚至超过电力变压器额定电流的不平衡情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.50
自引率
0.00%
发文量
0
期刊最新文献
Internet of things based smart photovoltaic panel monitoring system An efficient novel dual deep network architecture for video forgery detection Video saliency detection using modified high efficiency video coding and background modelling A novel compression methodology for medical images using deep learning for high-speed transmission Frequency reconfigurable microstrip patch antenna for multiband applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1