{"title":"Comparison of four different methods for the recovery of dotriacontane-16,17-14C from small animal respiratory tissue.","authors":"N Kmoch, G Reznik, H Haindl, U Mohr","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The efficiency and accuracy of four different methods of tissue preparation for the recovery of dotriacontane-16,17-14C (DOT-16,17-14C) from rat respiratory tissue were compared by means of liquid scintillation counting. A DOT-16,17-14C standard solution was placed on the respiratory epithelium of the nasal apex, larynx, trachea and main bronchi. Combustion of the lyophilized organs in a Packard sample oxidizer revealed the highest recovery and accuracy (93--100%), sample oxidizing by combustion without lyophilization the lowest recovery and accuracy (73--92%). Tissue solubilization by the commercially available tissue solubilizer TS-1 revealed a better recovery and accuracy (89--95%) than tissue maceration by boiling in methanolic KOH and toluene extraction (74--91%). Depending on the laboratory equipment, lyophilization or tissue solubilization is preferred; maceration and toluene extraction as well as combustion without freeze-drying are disregarded for further investigations because of the cumbersome procedure as well as the low recovery and accuracy, respectively.</p>","PeriodicalId":19324,"journal":{"name":"Nuclear-Medizin","volume":"14 2","pages":"185-91"},"PeriodicalIF":0.0000,"publicationDate":"1975-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear-Medizin","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The efficiency and accuracy of four different methods of tissue preparation for the recovery of dotriacontane-16,17-14C (DOT-16,17-14C) from rat respiratory tissue were compared by means of liquid scintillation counting. A DOT-16,17-14C standard solution was placed on the respiratory epithelium of the nasal apex, larynx, trachea and main bronchi. Combustion of the lyophilized organs in a Packard sample oxidizer revealed the highest recovery and accuracy (93--100%), sample oxidizing by combustion without lyophilization the lowest recovery and accuracy (73--92%). Tissue solubilization by the commercially available tissue solubilizer TS-1 revealed a better recovery and accuracy (89--95%) than tissue maceration by boiling in methanolic KOH and toluene extraction (74--91%). Depending on the laboratory equipment, lyophilization or tissue solubilization is preferred; maceration and toluene extraction as well as combustion without freeze-drying are disregarded for further investigations because of the cumbersome procedure as well as the low recovery and accuracy, respectively.