{"title":"Band width limits in wide band partial discharge calibration and corresponding countermeasures","authors":"Jianyin Liu, Zhong Zheng, Wei Feng, Xiaoyun Chen, Hong Yu, Zhiwei Huang, Rongliang Wang","doi":"10.1109/CEIDP.2013.6748174","DOIUrl":null,"url":null,"abstract":"Partial discharge (PD) measurement method defined in IEC60270 only captures the low frequency energy of measured signals, while more than 95% of the energy is distributed in the range of 30kHz~30MHz. Thus a high frequency wide band measurement method becomes fashionable to cover the entire bandwidth. In such frequency range, the influence of stray inductance and capacitance become dominant, especially in the conventional calibration process, where the calibration pulses are directly wired to the bushing through long single wires. In IEC bandwidth, this is not a problem since frequency is low. In high frequency, it makes the recorded calibration charge much smaller than the named quantity. Thus the calibration process becomes meaningless. This paper has studied such influence in a real 110kV transformer bushing through circuit analyses and real measurement. An innovative co-axial sensor is presented and shows good frequency response and measurement accuracy.","PeriodicalId":393969,"journal":{"name":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2013.6748174","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Partial discharge (PD) measurement method defined in IEC60270 only captures the low frequency energy of measured signals, while more than 95% of the energy is distributed in the range of 30kHz~30MHz. Thus a high frequency wide band measurement method becomes fashionable to cover the entire bandwidth. In such frequency range, the influence of stray inductance and capacitance become dominant, especially in the conventional calibration process, where the calibration pulses are directly wired to the bushing through long single wires. In IEC bandwidth, this is not a problem since frequency is low. In high frequency, it makes the recorded calibration charge much smaller than the named quantity. Thus the calibration process becomes meaningless. This paper has studied such influence in a real 110kV transformer bushing through circuit analyses and real measurement. An innovative co-axial sensor is presented and shows good frequency response and measurement accuracy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
宽带局部放电标定中的带宽限制及相应对策
IEC60270中定义的局部放电(Partial discharge, PD)测量方法只捕获被测信号的低频能量,而95%以上的能量分布在30kHz~30MHz范围内。因此,一种覆盖整个带宽的高频宽带测量方法成为一种时尚。在此频率范围内,杂散电感和电容的影响占主导地位,特别是在传统的校准过程中,校准脉冲通过长单线直接连接到套管上。在IEC带宽中,这不是问题,因为频率很低。在高频率下,它使记录的校准费用比命名量小得多。因此,校准过程变得毫无意义。本文通过电路分析和实测,研究了这种影响对实际110kV变压器套管的影响。提出了一种新型的同轴传感器,具有良好的频率响应和测量精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measurements of THz absorption peaks in photo-degraded polyethylene and their assignment by quantum chemical calculations Charge transport characteristics in epoxy resin at high temperatures based on electrode polarization analysis Experimental study on the dielectric properties of a liquid crystal polymer Influence of nano-titanium dioxide (TiO2) on electrical tree characteristics in silicone rubber based nanocomposite Phenomenon of secondary reverse streamer in an ester transformer liquid under lightning impulse voltage
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1