Design and Performance evaluation of Proposed 2 kW Solar PV Rooftop on Grid System in Odisha using PVsyst

Kamalesh Chandra Rout, P. Kulkarni
{"title":"Design and Performance evaluation of Proposed 2 kW Solar PV Rooftop on Grid System in Odisha using PVsyst","authors":"Kamalesh Chandra Rout, P. Kulkarni","doi":"10.1109/SCEECS48394.2020.124","DOIUrl":null,"url":null,"abstract":"Main factors driving towards renewable energy are the environmental effects and load demand of electricity. For residential as well as commercial applications, the primary purpose is to determine the methods driven by mathematical models for a grid-tied solar PV system. In Odisha state the average value of solar irradiation is around 1156.39 W/sq. m. So the solar rooftop plant of 1 kWp will generate on yearly basis an average value of 4.8 kWh of electricity per day (taking into account 5.5 sunshine hours). For the generation of 1 kWp, carbon dioxide discharges mitigated is 28 tonnes. So the installation is comparable of planting 45 trees over the life time. In this paper by using PVsyst V6.84 software a case study of 2 kW installation of solar PV plant on rooftop is analyzed for residential load utilization of 8.9 kWh/day. The simulation result gives available AC energy, used energy and excess energy. The generated excess energy is given to the utility grid. Therefore, development of this kind of system provides the green energy for storage and also worthwhile development of the society.","PeriodicalId":167175,"journal":{"name":"2020 IEEE International Students' Conference on Electrical,Electronics and Computer Science (SCEECS)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Students' Conference on Electrical,Electronics and Computer Science (SCEECS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCEECS48394.2020.124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

Main factors driving towards renewable energy are the environmental effects and load demand of electricity. For residential as well as commercial applications, the primary purpose is to determine the methods driven by mathematical models for a grid-tied solar PV system. In Odisha state the average value of solar irradiation is around 1156.39 W/sq. m. So the solar rooftop plant of 1 kWp will generate on yearly basis an average value of 4.8 kWh of electricity per day (taking into account 5.5 sunshine hours). For the generation of 1 kWp, carbon dioxide discharges mitigated is 28 tonnes. So the installation is comparable of planting 45 trees over the life time. In this paper by using PVsyst V6.84 software a case study of 2 kW installation of solar PV plant on rooftop is analyzed for residential load utilization of 8.9 kWh/day. The simulation result gives available AC energy, used energy and excess energy. The generated excess energy is given to the utility grid. Therefore, development of this kind of system provides the green energy for storage and also worthwhile development of the society.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
奥里萨邦2kw太阳能光伏屋顶并网系统的设计与性能评价
推动可再生能源发展的主要因素是环境影响和电力负荷需求。对于住宅和商业应用,主要目的是确定并网太阳能光伏系统的数学模型驱动方法。在奥里萨邦,太阳辐照的平均值约为1156.39 W/sq。m.因此,1 kWp的屋顶太阳能电站每年平均每天发电4.8 kWh(考虑到5.5日照小时)。发电1千瓦时,二氧化碳排放量减少28吨。所以这个装置相当于在一生中种了45棵树。本文利用PVsyst V6.84软件,以2kw屋顶太阳能光伏电站为例,对住宅8.9 kWh/d的负荷利用率进行了分析。仿真结果给出了可用交流能量、已用能量和多余能量。产生的多余能量被提供给公用电网。因此,这种系统的开发为存储提供了绿色能源,也是值得社会发展的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Various Types of Wireless Battery Management System in Ev Recognition of Faults in Grid Connected Solar Photovoltaic Farm Using Current Features Evaluated Using Stockwell Transform Based Algorithm Distracted Driver Detection using Stacking Ensemble Performance Analysis of Partial Shading on Solar Photovoltaic System under Aluminium Reflectors A Review on Prediction of Early Heart Attack Based on Degradation of Graphene Oxide and Carbon Nanotube using Myeloperoxidase
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1