Design of concrete-filled high strength steel tubular X-joints subjected to compression

Hai-ting Li, B. Young
{"title":"Design of concrete-filled high strength steel tubular X-joints subjected to compression","authors":"Hai-ting Li, B. Young","doi":"10.4995/ASCCS2018.2018.7062","DOIUrl":null,"url":null,"abstract":"The structural performance and design of concrete-filled high strength steel tubular X-joints subjected to compression are investigated. A numerical investigation on the behaviour of concrete-filled high strength steel tubular chord members under concentrated bearing load has been performed. The high strength steel tubes had nominal yield stresses of 700 and 900 MPa. The infilled concrete had nominal concrete cylinder strengths of 35 and 100 MPa. In order to avoid the failure of brace members and reveal the true capacity of the X-joints, steel bearing plates were used to simulate the brace members. A finite element model was developed and validated against test results. Furthermore, a parametric study comprised 156 finite element analyses was carried out. The strengths of the concrete-filled high strength steel square and rectangular hollow section X-joints obtained from the parametric study together with available data in the literature were compared with the nominal strengths calculated from the CIDECT Design Guide. It is shown that the CIDECT design predictions exhibit significant scatter and could be unconservative for the concrete-filled tubular joints with chord sidewall slenderness ratio beyond 40 in this study. Hence, new design rules are proposed for concrete-filled high strength steel tubular X-joints subjected to compression. It is shown that the proposed design rules are able to provide reasonably good predictions.","PeriodicalId":320267,"journal":{"name":"Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4995/ASCCS2018.2018.7062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The structural performance and design of concrete-filled high strength steel tubular X-joints subjected to compression are investigated. A numerical investigation on the behaviour of concrete-filled high strength steel tubular chord members under concentrated bearing load has been performed. The high strength steel tubes had nominal yield stresses of 700 and 900 MPa. The infilled concrete had nominal concrete cylinder strengths of 35 and 100 MPa. In order to avoid the failure of brace members and reveal the true capacity of the X-joints, steel bearing plates were used to simulate the brace members. A finite element model was developed and validated against test results. Furthermore, a parametric study comprised 156 finite element analyses was carried out. The strengths of the concrete-filled high strength steel square and rectangular hollow section X-joints obtained from the parametric study together with available data in the literature were compared with the nominal strengths calculated from the CIDECT Design Guide. It is shown that the CIDECT design predictions exhibit significant scatter and could be unconservative for the concrete-filled tubular joints with chord sidewall slenderness ratio beyond 40 in this study. Hence, new design rules are proposed for concrete-filled high strength steel tubular X-joints subjected to compression. It is shown that the proposed design rules are able to provide reasonably good predictions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高强度钢管混凝土x形节点受压设计
对高强钢管混凝土x形节点受压结构性能及设计进行了研究。对高强度钢管混凝土弦杆在集中荷载作用下的受力性能进行了数值研究。高强度钢管的标称屈服应力为700和900mpa。填充混凝土的标称混凝土柱强度分别为35和100 MPa。为了避免支撑构件的破坏,揭示x形节点的真实承载力,采用钢承载板对支撑构件进行模拟。建立了有限元模型,并对试验结果进行了验证。此外,还进行了包含156个有限元分析的参数化研究。将参数化研究得到的高强钢方形和矩形空心截面x形节点的强度与CIDECT设计指南中计算的标称强度进行了比较。结果表明,对于弦边长细比大于40的管状混凝土节点,CIDECT设计预测具有明显的离散性和非保守性。为此,提出了新的高强度钢管混凝土x形节点受压设计准则。结果表明,所提出的设计规则能够提供相当好的预测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel one-sided push-out test for shear connectors in composite beams Bending Moment Capacity of Stainless Steel-Concrete Composite Beams COMPARISON OF DESIGN FOR COMPOSITE COLUMNS IN STEEL AND CONCRETE ACCORDING TO EUROCODE 4 AND CHINESE DESIGN CODES An innovative concrete-steel structural system allowing for a fast and simple erection Influence of joint rigidity on the elastic buckling load of sway and non-sway steel frames
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1