Active Distribution System State Estimation: Comparison Between Weighted Least Squares and Extended Kalman Filter Algorithms

J. Watitwa, K. Awodele
{"title":"Active Distribution System State Estimation: Comparison Between Weighted Least Squares and Extended Kalman Filter Algorithms","authors":"J. Watitwa, K. Awodele","doi":"10.1109/PowerAfrica49420.2020.9219899","DOIUrl":null,"url":null,"abstract":"Power distribution systems have a topology which is typically unknown to the distribution system operators. Remote Terminal Units and SCADAs monitor these networks primarily at the substation level. However, with the widespread integration of Distributed Generation units (DGs), the need for real-time control of Active Distribution Networks is urgent. While DGs can improve the performance of power systems through voltage support, price elasticity, and reduced emissions of greenhouse gases, they also present challenges such as voltage spikes and bidirectional power flows. The distribution systems' state needs to be known accurately with high refresh rates and low time latency to deal with these issues. Real-time state estimation (SE) that use of Phasor Measurement Units (PMU) data allows the prediction of the distribution systems' nodal voltages and phasor angles. This paper presents a performance analysis comparison between the Weighted Least Square (WLS) and the Extended Kalman Filter (EKF) algorithms on active distribution grids. The WLS is a static SE algorithm, while EKF is a recursive SE method. The paper first recounts the analytical formulation of both approaches and then quantifies the differences in their performance. The tests were carried out on a modified IEEE-33 bus test feeder that included an optimally placed DG. For the test feeder's nodes load profile, the PMU-data generated during the ADRES-CONCEPT project was used. MATLAB and OpenDSS software were used to run the experiments. The results show that if the process model is correct, the EKF approach performs better.","PeriodicalId":325937,"journal":{"name":"2020 IEEE PES/IAS PowerAfrica","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE PES/IAS PowerAfrica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PowerAfrica49420.2020.9219899","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Power distribution systems have a topology which is typically unknown to the distribution system operators. Remote Terminal Units and SCADAs monitor these networks primarily at the substation level. However, with the widespread integration of Distributed Generation units (DGs), the need for real-time control of Active Distribution Networks is urgent. While DGs can improve the performance of power systems through voltage support, price elasticity, and reduced emissions of greenhouse gases, they also present challenges such as voltage spikes and bidirectional power flows. The distribution systems' state needs to be known accurately with high refresh rates and low time latency to deal with these issues. Real-time state estimation (SE) that use of Phasor Measurement Units (PMU) data allows the prediction of the distribution systems' nodal voltages and phasor angles. This paper presents a performance analysis comparison between the Weighted Least Square (WLS) and the Extended Kalman Filter (EKF) algorithms on active distribution grids. The WLS is a static SE algorithm, while EKF is a recursive SE method. The paper first recounts the analytical formulation of both approaches and then quantifies the differences in their performance. The tests were carried out on a modified IEEE-33 bus test feeder that included an optimally placed DG. For the test feeder's nodes load profile, the PMU-data generated during the ADRES-CONCEPT project was used. MATLAB and OpenDSS software were used to run the experiments. The results show that if the process model is correct, the EKF approach performs better.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
主动配电系统状态估计:加权最小二乘法与扩展卡尔曼滤波算法的比较
配电系统的拓扑结构通常是配电系统操作者所不知道的。远程终端单元和scada主要在变电站级别监视这些网络。然而,随着分布式发电机组(dg)的广泛集成,对有源配电网的实时控制需求日益迫切。虽然dg可以通过电压支持、价格弹性和减少温室气体排放来改善电力系统的性能,但它们也带来了电压尖峰和双向潮流等挑战。分配系统的状态需要通过高刷新率和低延迟来准确地了解,以处理这些问题。使用相量测量单元(PMU)数据的实时状态估计(SE)可以预测配电系统的节点电压和相角。本文对加权最小二乘(WLS)算法和扩展卡尔曼滤波(EKF)算法在主动配电网上的性能进行了分析比较。WLS是一种静态SE算法,EKF是一种递归SE方法。本文首先叙述了这两种方法的分析公式,然后量化了它们在性能上的差异。测试是在改进的IEEE-33总线测试馈线上进行的,该馈线包括一个最佳放置的DG。对于测试馈线节点的负载概况,使用了address - concept项目期间生成的pmu数据。采用MATLAB和OpenDSS软件进行实验。结果表明,在过程模型正确的情况下,EKF方法具有较好的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of the Levelized Cost of Electricity (LCOE) of Solar PV Systems Considering their Environmental Impacts on Biodiversity Conference Booklet Modeling the Impact of Power Generation on the Water Sector in the North, Eastern and Central African Power Pools Development of an IoT-Enabled-Dynamic Master Controller Model for the Integrated Afikpo Metropolitan Power Monitoring and Control System The Basics of Transmission Line Protection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1