Thallium lead iodide radiation detectors

K. Hitomi, T. Onodera, T. Shoji, Y. Hiratate
{"title":"Thallium lead iodide radiation detectors","authors":"K. Hitomi, T. Onodera, T. Shoji, Y. Hiratate","doi":"10.1109/NSSMIC.2002.1239360","DOIUrl":null,"url":null,"abstract":"Thallium lead iodide (TlPbI/sub 3/) is a compound semiconductor characterized with wide band gap (2.3 eV) and high photon stopping power. Thus, TlPbI/sub 3/ is an attractive material for fabrication of room temperature radiation detectors. In this study, TlPbI/sub 3/ crystals were grown by the vertical Bridgman technique using zone-purified materials. The starting materials for the crystal growth were synthesized from commercially available TlI and PbI/sub 2/ powders with nominal purity of 99.99%. Powder X-ray diffraction analysis was performed to evaluate chemical composition of the synthesized TlPbI/sub 3/. In order to fabricate radiation detectors, the grown crystals were cut into several wafers using a wire saw. The wafers were then polished using Al/sub 2/O/sub 3/ abrasives. Electrodes were formed on the wafers by vacuum evaporation of gold. The resultant TlPbI/sub 3/ radiation detectors were evaluated by measuring their current-voltage characteristics and spectral responses. Most of TlPbI/sub 3/ detectors exhibited resistivities more than 10/sup 11/ /spl Omega/cm. The TlPbI/sub 3/ detectors were irradiated with /spl alpha/-particles (5.48 MeV) from a /sup 241/Am source or /spl gamma/-rays (662 keV) from a /sup 137/Cs source. The TlPbI/sub 3/ detectors exhibited a clear peak of 5.48 MeV /spl alpha/-particles. Although the 662 keV peak was not resolved in the energy spectra, increased counts above the noise spectrum were observed for the detectors. To our knowledge, it is the first time that TlPbI/sub 3/ detectors exhibit /spl alpha/-particle spectra with a clear peak and /spl gamma/-ray spectra.","PeriodicalId":385259,"journal":{"name":"2002 IEEE Nuclear Science Symposium Conference Record","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Nuclear Science Symposium Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2002.1239360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

Thallium lead iodide (TlPbI/sub 3/) is a compound semiconductor characterized with wide band gap (2.3 eV) and high photon stopping power. Thus, TlPbI/sub 3/ is an attractive material for fabrication of room temperature radiation detectors. In this study, TlPbI/sub 3/ crystals were grown by the vertical Bridgman technique using zone-purified materials. The starting materials for the crystal growth were synthesized from commercially available TlI and PbI/sub 2/ powders with nominal purity of 99.99%. Powder X-ray diffraction analysis was performed to evaluate chemical composition of the synthesized TlPbI/sub 3/. In order to fabricate radiation detectors, the grown crystals were cut into several wafers using a wire saw. The wafers were then polished using Al/sub 2/O/sub 3/ abrasives. Electrodes were formed on the wafers by vacuum evaporation of gold. The resultant TlPbI/sub 3/ radiation detectors were evaluated by measuring their current-voltage characteristics and spectral responses. Most of TlPbI/sub 3/ detectors exhibited resistivities more than 10/sup 11/ /spl Omega/cm. The TlPbI/sub 3/ detectors were irradiated with /spl alpha/-particles (5.48 MeV) from a /sup 241/Am source or /spl gamma/-rays (662 keV) from a /sup 137/Cs source. The TlPbI/sub 3/ detectors exhibited a clear peak of 5.48 MeV /spl alpha/-particles. Although the 662 keV peak was not resolved in the energy spectra, increased counts above the noise spectrum were observed for the detectors. To our knowledge, it is the first time that TlPbI/sub 3/ detectors exhibit /spl alpha/-particle spectra with a clear peak and /spl gamma/-ray spectra.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
碘化铊铅辐射探测器
碘化铊铅(TlPbI/ sub3 /)是一种具有宽禁带(2.3 eV)和高光子阻挡能力的化合物半导体。因此,TlPbI/sub 3/是制造室温辐射探测器的理想材料。在本研究中,使用区域纯化材料,采用垂直Bridgman技术生长了TlPbI/sub - 3/晶体。晶体生长的起始材料是由市售的TlI和PbI/sub 2/粉末合成的,其标称纯度为99.99%。对合成的TlPbI/sub - 3/进行了粉末x射线衍射分析。为了制造辐射探测器,用钢丝锯把生长的晶体切成几片晶圆。然后使用Al/sub 2/O/sub 3/磨料对晶圆进行抛光。通过真空蒸发金在晶圆上形成电极。通过测量其电流-电压特性和光谱响应来评价所得到的TlPbI/sub - 3/辐射探测器。大多数TlPbI/sub - 3/探测器的电阻率大于10/sup 11/ spl ω /cm。用/sup 241/Am源的/spl α /-粒子(5.48 MeV)和/sup 137/Cs源的/spl γ /-射线(662 keV)照射TlPbI/sub - 3/探测器。TlPbI/ sub3 /探测器显示出5.48 MeV /spl α /-粒子的清晰峰值。虽然662 keV的峰值在能谱中没有被分辨出来,但在噪声谱上观察到探测器的计数增加。据我们所知,这是TlPbI/ sub3 /探测器首次表现出具有清晰峰的/spl α /-粒子光谱和/spl γ /-射线光谱。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Real-time data reorganizer for the D0 central fiber tracker trigger system at Fermilab A CMOS active pixel sensor for charged particle detection A high-speed, low-noise CMOS 16-channel charge-sensitive preamplifier ASIC for APD-based PET detectors Advantages of improved timing accuracy in PET cameras using LSO scintillator Temporal resolution properties of dynamic PET reconstructions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1