{"title":"A Study of Accuracy of Brightness Temperature and Retrieval Products From Ground-based Microwave Radiometer","authors":"Qiuchen Zhang, Jun Wang","doi":"10.1109/ICMO49322.2019.9026140","DOIUrl":null,"url":null,"abstract":"Ground-based microwave radiometer (MWR) utilizes in this study is RPG-HTAPRO-G3, which measures the atmospheric radiation characteristics at 7 oxygen channels and 7 water vapor channels to obtain atmospheric thermodynamic profiles. The reliability of 14 channels brightness temperature (BT)from MWR is tested by contrasting the BTs simulated by the monochromatic radiative transfer model MonoRTM in Linux with that observed by MWR. The results show that BTs of oxygen channels have better correlation and consistency than BTs of water vapor channels. The correlation coefficients are 0.99 and 0.92 respectively. By comparing the mean bias (MB) and root-mean-square error (RMSE) of retrieval products from MWR and L-band radiosonde in different height of non-rainy day, temperature below 4000m is generally more accurate than in other height, the value of MB of temperature is -1.5-1.0.The difference of MB and RMSE of water vapor density is small and consistent. The MB value of water vapor density is positive. The RMSE of water vapor density (0-0.6 g/m3) decreases with height. The MB and RMSE of relative humidity are higher than temperature and water vapor density obviously. Atmospheric instability indices, such like K Index (KI), Lifting Index (LI), Showalter Index (SI), Total Total Index (TTI) and Convective Available Potential Energy (CAPE) derived from MWR are examined by the L-band radiosonde data in one year. The results show that correlation coefficients of 5 instability indices are 0.72, 0.93 0.86,0.76 and0.62.","PeriodicalId":257532,"journal":{"name":"2019 International Conference on Meteorology Observations (ICMO)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Meteorology Observations (ICMO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMO49322.2019.9026140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Ground-based microwave radiometer (MWR) utilizes in this study is RPG-HTAPRO-G3, which measures the atmospheric radiation characteristics at 7 oxygen channels and 7 water vapor channels to obtain atmospheric thermodynamic profiles. The reliability of 14 channels brightness temperature (BT)from MWR is tested by contrasting the BTs simulated by the monochromatic radiative transfer model MonoRTM in Linux with that observed by MWR. The results show that BTs of oxygen channels have better correlation and consistency than BTs of water vapor channels. The correlation coefficients are 0.99 and 0.92 respectively. By comparing the mean bias (MB) and root-mean-square error (RMSE) of retrieval products from MWR and L-band radiosonde in different height of non-rainy day, temperature below 4000m is generally more accurate than in other height, the value of MB of temperature is -1.5-1.0.The difference of MB and RMSE of water vapor density is small and consistent. The MB value of water vapor density is positive. The RMSE of water vapor density (0-0.6 g/m3) decreases with height. The MB and RMSE of relative humidity are higher than temperature and water vapor density obviously. Atmospheric instability indices, such like K Index (KI), Lifting Index (LI), Showalter Index (SI), Total Total Index (TTI) and Convective Available Potential Energy (CAPE) derived from MWR are examined by the L-band radiosonde data in one year. The results show that correlation coefficients of 5 instability indices are 0.72, 0.93 0.86,0.76 and0.62.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
地面微波辐射计亮度温度及反演产品精度研究
本研究采用的地基微波辐射计是RPG-HTAPRO-G3,通过测量7个氧通道和7个水蒸气通道的大气辐射特性,得到大气热力学剖面图。通过对比Linux中单色辐射传输模型MonoRTM模拟的14通道亮度温度(BT)与MWR观测的亮度温度,验证了MWR的可靠性。结果表明,氧通道的热通量比水蒸气通道的热通量具有更好的相关性和一致性。相关系数分别为0.99和0.92。通过比较MWR和l波段探空仪在非雨天不同高度反演产品的平均偏差(MB)和均方根误差(RMSE),温度在4000m以下普遍比其他高度更准确,温度的MB值为-1.5 ~ 1.0。水汽密度的MB和RMSE的差异较小且一致。水汽密度的MB值为正。水汽密度RMSE (0 ~ 0.6 g/m3)随高度减小。相对湿度的MB和RMSE明显高于温度和水汽密度。利用1年的l波段探空资料,对MWR反演的K指数(KI)、升力指数(LI)、Showalter指数(SI)、Total Total指数(TTI)和对流有效势能(CAPE)等大气不稳定指标进行了研究。结果表明,5个不稳定性指标的相关系数分别为0.72、0.93、0.86、0.76和0.62。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Improvement of L-band Wind Profile Radar System Research and Application of Meteorological Data Transmission System Based on Virtual Desktop Design and implementation of the maximum dimension algorithm for ice crystal particles recorded by 2D image probe Design and Implementation of Intelligent Support System for National Ground Observation Stations in Guizhou Design and Implementation of Signal Processing for Software Doppler Weather Radar
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1