{"title":"Improved Positive and Negative Sequence Double Loop Control Strategy for Cascaded STATCOM under Grid Voltage Imbalance","authors":"Shengqing Li, Wang Han, Zhijian Wang, Jiaxing Yu","doi":"10.1145/3386415.3387049","DOIUrl":null,"url":null,"abstract":"Aiming at the issue of reactive power and negative sequence current compensation of cascaded static synchronous compensator (STATCOM) and the problems of DC-side voltage equalization under grid voltage imbalance, an improved positive and negative sequence double loop control method is proposed. Through the independent control of positive and negative sequence active and reactive power, the global voltage regulation control of the device is realized while realizing reactive and negative sequence current compensation. A phase-injection voltage is applied between the phases to balance the phase-to-phase power and achieve phase-tophase voltage equalization. The simulation results evidence that the proposed method can not only well compensate the reactive power and negative sequence current, in case of unbalanced grid voltage well, but also effectively solve the DC side voltage balance problem.","PeriodicalId":250211,"journal":{"name":"Proceedings of the 2nd International Conference on Information Technologies and Electrical Engineering","volume":"161 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2nd International Conference on Information Technologies and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3386415.3387049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Aiming at the issue of reactive power and negative sequence current compensation of cascaded static synchronous compensator (STATCOM) and the problems of DC-side voltage equalization under grid voltage imbalance, an improved positive and negative sequence double loop control method is proposed. Through the independent control of positive and negative sequence active and reactive power, the global voltage regulation control of the device is realized while realizing reactive and negative sequence current compensation. A phase-injection voltage is applied between the phases to balance the phase-to-phase power and achieve phase-tophase voltage equalization. The simulation results evidence that the proposed method can not only well compensate the reactive power and negative sequence current, in case of unbalanced grid voltage well, but also effectively solve the DC side voltage balance problem.