{"title":"Calibration of multi-focal planes for zoom-lens unit","authors":"Jyun-Cheng Huang, Chien-Sheng Liu, Yule Huang","doi":"10.1109/ICSENST.2017.8304441","DOIUrl":null,"url":null,"abstract":"In this paper, the calibration method of multi-focal planes of a 3D scanning system with zoom-lens unit based on structured light has been discussed. Based on the development of calibration methods for zoom lens characteristics, we design a calibration target for zoom lens calibration. Also, we present a pragmatic calibration process that consists of five procedures.","PeriodicalId":289209,"journal":{"name":"2017 Eleventh International Conference on Sensing Technology (ICST)","volume":"297 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Eleventh International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2017.8304441","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this paper, the calibration method of multi-focal planes of a 3D scanning system with zoom-lens unit based on structured light has been discussed. Based on the development of calibration methods for zoom lens characteristics, we design a calibration target for zoom lens calibration. Also, we present a pragmatic calibration process that consists of five procedures.