S. Komarizadehasl, Ahmad Alahmad, J. Lozano-Galant, V. Torralba, G. Ramos, J. Turmo
{"title":"Beneficial Effect of Combining Similar Low-Cost Accelerometer to improve the overall Accuracy and Noise Density","authors":"S. Komarizadehasl, Ahmad Alahmad, J. Lozano-Galant, V. Torralba, G. Ramos, J. Turmo","doi":"10.2749/nanjing.2022.1256","DOIUrl":null,"url":null,"abstract":"Structural Health Monitoring applications are receiving more and more attention nowadays. The epidemic problem with these evaluations is their high cost. For applying them to structures/ infrastructures with a low budget of SHM evaluations, low-cost sensors must be taken into account. However, low-cost accelerometers have higher noise density ratios which affect their accuracy and resolution. Using filters or post-processing methods alters the acquired information of the accelerometers. This article aims to enhance the accuracy and resolution of low-cost sensors by improving and controlling the spectral noise level through active noise improvement. This improvement is studied in this paper and supportive laboratory experiments have been illustrated.","PeriodicalId":410450,"journal":{"name":"IABSE Congress, Nanjing 2022: Bridges and Structures: Connection, Integration and Harmonisation","volume":"140 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IABSE Congress, Nanjing 2022: Bridges and Structures: Connection, Integration and Harmonisation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2749/nanjing.2022.1256","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Structural Health Monitoring applications are receiving more and more attention nowadays. The epidemic problem with these evaluations is their high cost. For applying them to structures/ infrastructures with a low budget of SHM evaluations, low-cost sensors must be taken into account. However, low-cost accelerometers have higher noise density ratios which affect their accuracy and resolution. Using filters or post-processing methods alters the acquired information of the accelerometers. This article aims to enhance the accuracy and resolution of low-cost sensors by improving and controlling the spectral noise level through active noise improvement. This improvement is studied in this paper and supportive laboratory experiments have been illustrated.