{"title":"Power Quality Investigation by Reduced Switching UPQC","authors":"Pradeep Kumar","doi":"10.18280/ejee.224-505","DOIUrl":null,"url":null,"abstract":"Received: 27 February 2020 Accepted: 6 June 2020 In this paper, nine switches UPQC topology with different control techniques have been depicted and compared their performances to accomplish clear inspection of the best control techniques. As conventional UPQC having twelve switches of six legs enhances the switching losses, circuit complication, costly etc. Hence nine switches UPQC topology is intended to reduce the switching losses, complexity, size and cost. This proposed topology has only three legs with three switches in each leg making total number of nine switches. The three control techniques such as Unit vector template, PQ theory and Synchronous reference frame theory have been employed in the nine switch UPQC topology. The simulation has been carried out separately for each control technique in MATLAB/SIMPOWER environment and results have been verified for higher efficiency of nine switch UPQC topology. The comparative THD of source currents and load voltages under these control techniques have been analysed. The obtained THD values are below 5% as per IEEE-519 standard.","PeriodicalId":340029,"journal":{"name":"European Journal of Electrical Engineering","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18280/ejee.224-505","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Received: 27 February 2020 Accepted: 6 June 2020 In this paper, nine switches UPQC topology with different control techniques have been depicted and compared their performances to accomplish clear inspection of the best control techniques. As conventional UPQC having twelve switches of six legs enhances the switching losses, circuit complication, costly etc. Hence nine switches UPQC topology is intended to reduce the switching losses, complexity, size and cost. This proposed topology has only three legs with three switches in each leg making total number of nine switches. The three control techniques such as Unit vector template, PQ theory and Synchronous reference frame theory have been employed in the nine switch UPQC topology. The simulation has been carried out separately for each control technique in MATLAB/SIMPOWER environment and results have been verified for higher efficiency of nine switch UPQC topology. The comparative THD of source currents and load voltages under these control techniques have been analysed. The obtained THD values are below 5% as per IEEE-519 standard.