Aerosol sizing by laser Doppler relaxation-time measurement

M. Mazumder, S. N. Nichols, R. Overbey
{"title":"Aerosol sizing by laser Doppler relaxation-time measurement","authors":"M. Mazumder, S. N. Nichols, R. Overbey","doi":"10.1364/cleos.1976.tuf3","DOIUrl":null,"url":null,"abstract":"Methods using laser Doppler velocimeters have been developed for measuring the dynamic relaxation time (τ\n p\n ) of aerosol particles and droplets. For real-time measurement of aerodynamic size spectra in the range of 0.2-50.0 μm in diameter, the most promising methods employ (1) acoustic excitation, for the size range of 0.2-5.0 μm in diameter, and (2) gravity settling, for the size range of 5.0-50.0 μm in diameter. Both methods have been applied to rapid in situ measurement of the size distribution of stable and unstable aerosols. Experimental results indicate that these newly developed methods compliment the existing methods of real-time aerosol size analysis.","PeriodicalId":301658,"journal":{"name":"Conference on Laser and Electrooptical Systems","volume":"177 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Laser and Electrooptical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/cleos.1976.tuf3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Methods using laser Doppler velocimeters have been developed for measuring the dynamic relaxation time (τ p ) of aerosol particles and droplets. For real-time measurement of aerodynamic size spectra in the range of 0.2-50.0 μm in diameter, the most promising methods employ (1) acoustic excitation, for the size range of 0.2-5.0 μm in diameter, and (2) gravity settling, for the size range of 5.0-50.0 μm in diameter. Both methods have been applied to rapid in situ measurement of the size distribution of stable and unstable aerosols. Experimental results indicate that these newly developed methods compliment the existing methods of real-time aerosol size analysis.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
激光多普勒弛豫时间测量气溶胶粒径
使用激光多普勒测速仪测量气溶胶粒子和液滴的动态弛豫时间(τ p)的方法已经发展起来。对于直径0.2 ~ 50.0 μm范围内气动尺寸谱的实时测量,最具应用前景的方法是:(1)直径0.2 ~ 5.0 μm范围内的声激励和(2)直径5.0 ~ 50.0 μm范围内的重力沉降。这两种方法都已应用于稳定和不稳定气溶胶粒径分布的快速原位测量。实验结果表明,这些新方法是对现有气溶胶粒径实时分析方法的补充。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of the fusion-effectiveness of active and passive pulse-stackers Design techniques and measured performance for a uniformly pumped 4-cm diam rod amplifier Focusing lenses for the 20-beam fusion laser: SHIVA Laser isotope separation: a revolution in chemistry Far infrared difference frequency generation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1