Analysis of power quality problems in grid connected wind power plant

M. G. Sugirtha, P. Latha
{"title":"Analysis of power quality problems in grid connected wind power plant","authors":"M. G. Sugirtha, P. Latha","doi":"10.1109/ICONRAEECE.2011.6129727","DOIUrl":null,"url":null,"abstract":"Wind energy is one of the fastest-growing sources of electricity in India and around the world. In spite of being cheap, clean and abundant the continuous fluctuations in the renewable energy causes significant power quality issues. This paper presents a technical review of power quality problems associated with grid connected wind power plant and describes the Dynamic Voltage Restorer that injects voltage into the system with a view to enhance the network power factor while stabilizing the voltage and reducing the network losses. On the basis of measurements and norms followed according to the guidelines specified in IEC-61400 (International Electro-technical Commission) standard, the performance of the wind turbine and thereby power quality should be determined. Wind turbines, especially of Induction type, can draw large amount of reactive power from the grid. Insufficient supply of reactive power from the grid to the wind generators may cause voltage stability problems. To minimize reactive power exchange between wind generators and grid, dynamic compensation of reactive power can be employed by using DVR. This paper also describes the analysis of Dynamic Voltage Restorer (DVR) using MATLAB/SIMULINK for the grid connected Wind Power Plant.","PeriodicalId":305797,"journal":{"name":"2011 INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENTS IN ELECTRICAL, ELECTRONICS AND CONTROL ENGINEERING","volume":"110 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENTS IN ELECTRICAL, ELECTRONICS AND CONTROL ENGINEERING","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICONRAEECE.2011.6129727","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

Abstract

Wind energy is one of the fastest-growing sources of electricity in India and around the world. In spite of being cheap, clean and abundant the continuous fluctuations in the renewable energy causes significant power quality issues. This paper presents a technical review of power quality problems associated with grid connected wind power plant and describes the Dynamic Voltage Restorer that injects voltage into the system with a view to enhance the network power factor while stabilizing the voltage and reducing the network losses. On the basis of measurements and norms followed according to the guidelines specified in IEC-61400 (International Electro-technical Commission) standard, the performance of the wind turbine and thereby power quality should be determined. Wind turbines, especially of Induction type, can draw large amount of reactive power from the grid. Insufficient supply of reactive power from the grid to the wind generators may cause voltage stability problems. To minimize reactive power exchange between wind generators and grid, dynamic compensation of reactive power can be employed by using DVR. This paper also describes the analysis of Dynamic Voltage Restorer (DVR) using MATLAB/SIMULINK for the grid connected Wind Power Plant.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
并网风力发电厂电能质量问题分析
风能是印度乃至全世界发展最快的电力来源之一。尽管可再生能源便宜、清洁、丰富,但其持续的波动导致了严重的电能质量问题。本文介绍了与并网风力发电厂相关的电能质量问题的技术综述,并描述了动态电压恢复器,它向系统注入电压,以提高网络功率因数,同时稳定电压,减少网络损耗。根据IEC-61400(国际电工委员会)标准中规定的准则,在测量和规范的基础上,应确定风力涡轮机的性能,从而确定电能质量。风力发电机,特别是感应式风力发电机,可以从电网中吸收大量的无功功率。电网向风力发电机提供的无功功率不足可能会导致电压稳定问题。为了最大限度地减少风电机组与电网之间的无功交换,可以采用DVR对无功进行动态补偿。本文还介绍了利用MATLAB/SIMULINK对并网风电场的动态电压恢复器(DVR)进行分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Iris recognition using Ridgelet transform Analog control scheme for Cascaded Multilevel Inverters based on multiple carrier PWM technique Energy balance model based fuzzy controller for combustion of utility boiler Design of PID power system stabilizer using GA for SMIB system: Linear and non-linear approach Dielectric properties of polycarbonate coated natural fabric Grewia tilifolia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1