{"title":"Power transformer oil–paper insulation degradation modelling and prediction method based on functional principal component analysis","authors":"Yuehan Qu,&nbsp;Hongshan Zhao,&nbsp;Shice Zhao,&nbsp;Libo Ma,&nbsp;Zengqiang Mi","doi":"10.1049/smt2.12117","DOIUrl":null,"url":null,"abstract":"<p>This study is for the case where the available data of power transformer oil–paper insulation is limited to a small amount furfural data, to solve the problems in oil–paper insulation degradation modelling, such as few samples available, unknown function form of the degradation process, differences of individual transformers among degradation processes, and commonality of degradation trends. A power transformer oil–paper insulation degradation modelling and prediction method based on functional principal component analysis (FPCA) is proposed. First, discrete furfural data of oil–paper insulation degradation are converted into continuous functional data, and the common degradation information of transformers is extracted based on functional time warping technology. Second, the principal components of insulation degradation are extracted based on FPCA method, and the difference of degradation information of individual transformers is obtained by analysing the differential of principal component scores. Subsequently, power transformer oil–paper insulation degradation model is constructed, and finally, the degradation model is updated based on Bayesian theory and the oil–paper insulation degradation is predicted. The example results show that compared with traditional transformer oil–paper insulation degradation modelling method, the proposed method has obvious superiority in model accuracy.</p>","PeriodicalId":54999,"journal":{"name":"Iet Science Measurement & Technology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2022-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ietresearch.onlinelibrary.wiley.com/doi/epdf/10.1049/smt2.12117","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Science Measurement & Technology","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/smt2.12117","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 1

Abstract

This study is for the case where the available data of power transformer oil–paper insulation is limited to a small amount furfural data, to solve the problems in oil–paper insulation degradation modelling, such as few samples available, unknown function form of the degradation process, differences of individual transformers among degradation processes, and commonality of degradation trends. A power transformer oil–paper insulation degradation modelling and prediction method based on functional principal component analysis (FPCA) is proposed. First, discrete furfural data of oil–paper insulation degradation are converted into continuous functional data, and the common degradation information of transformers is extracted based on functional time warping technology. Second, the principal components of insulation degradation are extracted based on FPCA method, and the difference of degradation information of individual transformers is obtained by analysing the differential of principal component scores. Subsequently, power transformer oil–paper insulation degradation model is constructed, and finally, the degradation model is updated based on Bayesian theory and the oil–paper insulation degradation is predicted. The example results show that compared with traditional transformer oil–paper insulation degradation modelling method, the proposed method has obvious superiority in model accuracy.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于功能主成分分析的电力变压器油纸绝缘退化建模与预测方法
本研究针对电力变压器油纸绝缘可用数据限于少量糠醛数据的情况,解决油纸绝缘退化建模中可用样本少、退化过程函数形式未知、个别变压器退化过程之间存在差异、退化趋势具有共性等问题。提出了一种基于功能主成分分析(FPCA)的电力变压器油纸绝缘退化建模与预测方法。首先,将油纸绝缘退化的离散糠醛数据转换为连续函数数据,并基于函数时间规整技术提取变压器的常见退化信息;其次,基于FPCA方法提取绝缘退化主成分,通过分析主成分评分的差异,得到各变压器绝缘退化信息的差异性;建立了电力变压器油纸绝缘退化模型,最后基于贝叶斯理论对退化模型进行了更新,并对油纸绝缘退化进行了预测。算例结果表明,与传统的变压器油纸绝缘退化建模方法相比,该方法在模型精度上具有明显的优越性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iet Science Measurement & Technology
Iet Science Measurement & Technology 工程技术-工程:电子与电气
CiteScore
4.30
自引率
7.10%
发文量
41
审稿时长
7.5 months
期刊介绍: IET Science, Measurement & Technology publishes papers in science, engineering and technology underpinning electronic and electrical engineering, nanotechnology and medical instrumentation.The emphasis of the journal is on theory, simulation methodologies and measurement techniques. The major themes of the journal are: - electromagnetism including electromagnetic theory, computational electromagnetics and EMC - properties and applications of dielectric, magnetic, magneto-optic, piezoelectric materials down to the nanometre scale - measurement and instrumentation including sensors, actuators, medical instrumentation, fundamentals of measurement including measurement standards, uncertainty, dissemination and calibration Applications are welcome for illustrative purposes but the novelty and originality should focus on the proposed new methods.
期刊最新文献
Research on the online monitoring technique for transformer oil level based on ultrasonic sensors Reconstruction of rough surfaces from a single receiver at grazing angle Thermal behaviour of a transformer mineral oil-tank surface under incipient turn-to-turn short-circuit fault Simultaneous electromagnetic field probing system with Y-shaped separation detection structure Analysis of electrical contact characteristics of strap contacts used in high voltage bushings under eccentric conditions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1