Plateletworks™ Platelet Function Test Compared to the Thromboelastograph™ for Prediction of Postoperative Outcomes

J. Ostrowsky, Jennifer Foes, M. Warchol, Gary Tsarovsky, J. Blay
{"title":"Plateletworks™ Platelet Function Test Compared to the Thromboelastograph™ for Prediction of Postoperative Outcomes","authors":"J. Ostrowsky, Jennifer Foes, M. Warchol, Gary Tsarovsky, J. Blay","doi":"10.1051/ject/2004362149","DOIUrl":null,"url":null,"abstract":"Approximately 3.5 million units of platelets are transfused in the United States each year to patients undergoing open-heart surgery with cardiopulmonary bypass (CPB). CPB is a known contributor to platelet loss and platelet dysfunction leading to disruption of hemostasis. Impaired hemostasis results in excess bleeding in 5–25% of all patients undergoing CPB. For this reason, it may be beneficial to measure platelet number and function in these patients. The purpose of this study was to compare the Plateletworks™ platelet function analyzer to the thromboelastograph (TEG) in predicting postoperatiave hemostatic outcomes as measured by blood product use and chest tube (CT) drainage. This study consisted of 35 adult patients undergoing cardiac surgery with cardiopulmonary bypass at Rush-Presbyterian-Saint Luke’s Medical Center (RPSLMC). The Plateletworks™ and TEG tests were performed preoperatively, after protamine was given, and 24 hours postoperatively on all patients. Plateletworks™ demonstrated a statistically significant change in platelet function as shown by the adenosine diphosphate (ADP) reagent tube from the preoperative period to the removal of the aortic cross clamp (p = .011). The TEG did not demonstrate a significant change in the k-time and maximum amplitude (MA), but did show a significant change in the alpha-angle from the pre-operative to postoperatiave sample (p = .035). A correlation was found between Plateletworks™ collagen reagent tubes preoperatively and CT drainage (p = .048, r −0.324). No statistical correlation was established between TEG parameters and CT drainage at any time interval. TEG preoperative MA showed a correlation to receipt of blood products (p = .016). When comparing the Plateletworks™ to the TEG in this study, the Plateletworks™ system was a more useful predictor of blood product use and chest tube drainage.","PeriodicalId":309024,"journal":{"name":"The Journal of ExtraCorporeal Technology","volume":"140 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of ExtraCorporeal Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ject/2004362149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30

Abstract

Approximately 3.5 million units of platelets are transfused in the United States each year to patients undergoing open-heart surgery with cardiopulmonary bypass (CPB). CPB is a known contributor to platelet loss and platelet dysfunction leading to disruption of hemostasis. Impaired hemostasis results in excess bleeding in 5–25% of all patients undergoing CPB. For this reason, it may be beneficial to measure platelet number and function in these patients. The purpose of this study was to compare the Plateletworks™ platelet function analyzer to the thromboelastograph (TEG) in predicting postoperatiave hemostatic outcomes as measured by blood product use and chest tube (CT) drainage. This study consisted of 35 adult patients undergoing cardiac surgery with cardiopulmonary bypass at Rush-Presbyterian-Saint Luke’s Medical Center (RPSLMC). The Plateletworks™ and TEG tests were performed preoperatively, after protamine was given, and 24 hours postoperatively on all patients. Plateletworks™ demonstrated a statistically significant change in platelet function as shown by the adenosine diphosphate (ADP) reagent tube from the preoperative period to the removal of the aortic cross clamp (p = .011). The TEG did not demonstrate a significant change in the k-time and maximum amplitude (MA), but did show a significant change in the alpha-angle from the pre-operative to postoperatiave sample (p = .035). A correlation was found between Plateletworks™ collagen reagent tubes preoperatively and CT drainage (p = .048, r −0.324). No statistical correlation was established between TEG parameters and CT drainage at any time interval. TEG preoperative MA showed a correlation to receipt of blood products (p = .016). When comparing the Plateletworks™ to the TEG in this study, the Plateletworks™ system was a more useful predictor of blood product use and chest tube drainage.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Plateletworks™血小板功能试验与Thromboelastograph™预测术后预后的比较
在美国,每年大约有350万单位的血小板输注给接受体外循环(CPB)的心内直视手术的患者。CPB是一种已知的血小板损失和血小板功能障碍导致止血中断的因素。在所有接受CPB的患者中,有5-25%的患者止血受损导致出血过多。因此,在这些患者中测量血小板数量和功能可能是有益的。本研究的目的是比较Plateletworks™血小板功能分析仪与血栓弹性描画仪(TEG)在预测术后止血结果方面的差异,这些结果是通过血液制品使用和胸管(CT)引流来测量的。本研究包括在拉什-长老会-圣卢克医疗中心(RPSLMC)接受心脏手术和体外循环的35名成年患者。所有患者术前、给予鱼精蛋白后和术后24小时分别进行Plateletworks™和TEG检测。Plateletworks™显示,从术前到移除主动脉十字钳期间,二磷酸腺苷(ADP)试剂管显示血小板功能有统计学意义的变化(p = 0.011)。TEG在k-time和最大振幅(MA)上没有明显变化,但在α角上从术前到术后有明显变化(p = 0.035)。术前Plateletworks™胶原试剂管与CT引流有相关性(p = 0.048, r−0.324)。TEG参数与CT引流在任何时间间隔均无统计学相关性。TEG术前MA与接受血液制品相关(p = 0.016)。在本研究中将Plateletworks™与TEG进行比较时,Plateletworks™系统是血液制品使用和胸管引流的更有用的预测指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Standardized Therapies after ECMO Program (STEP); A Novel Approach to Pediatric post-ECMO Care Traditional vs. modified Ringer lactate-based del Nido cardioplegia impacts on clinical outcomes in patients undergoing coronary artery bypass grafting: results from a clinical trial Comparison of routine del Nido cardioplegia vs two types of modified del Nido cardioplegias for myocardial protection among patients undergoing coronary artery bypass grafting (CABG) surgeries: a randomized double-blind clinical trial. Adapting and Applying Student-centered Learning in a Perfusion Clinical Rotation Adapting and Applying Student-centered Learning in a Perfusion Clinical Rotation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1