{"title":"A Microcontroller Based Heart Rate Monitoring and Conditions Detection System","authors":"Faiza Jibril, Steve A. Adeshina, Sadiq Thomas, Ali Nyangwarimam Obadia, Oiza Sala, Oluwatomisin E. Aina","doi":"10.1109/ICECCO48375.2019.9043190","DOIUrl":null,"url":null,"abstract":"Cardio Vascular Disease is one of the leading causes of deaths in Nigeria with a staggering number of about 150,000 deaths annually as compiled by the Nigerian Heart Foundation (NHF). A good number of these deaths are a result of wrong observation and late detection of the disease. This system provides a means of reducing the number of deaths caused by cardiovascular diseases through the design and implementation of a portable and cost-effective device for the detection and monitoring of heart rate conditions. System performance testing was carried out by measuring the pulse rate and detecting the state of the heart at 5-minute intervals for 50 minutes. The produced results of the system show an average error of 2.8% in comparison to the data measured by the application of Cardiac diagnosis and an error of 2.2% in comparison to the traditional means of measuring heart rate. Hence the designed system can be used effectively to monitor and detect cardiovascular diseases.","PeriodicalId":166322,"journal":{"name":"2019 15th International Conference on Electronics, Computer and Computation (ICECCO)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 15th International Conference on Electronics, Computer and Computation (ICECCO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECCO48375.2019.9043190","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Cardio Vascular Disease is one of the leading causes of deaths in Nigeria with a staggering number of about 150,000 deaths annually as compiled by the Nigerian Heart Foundation (NHF). A good number of these deaths are a result of wrong observation and late detection of the disease. This system provides a means of reducing the number of deaths caused by cardiovascular diseases through the design and implementation of a portable and cost-effective device for the detection and monitoring of heart rate conditions. System performance testing was carried out by measuring the pulse rate and detecting the state of the heart at 5-minute intervals for 50 minutes. The produced results of the system show an average error of 2.8% in comparison to the data measured by the application of Cardiac diagnosis and an error of 2.2% in comparison to the traditional means of measuring heart rate. Hence the designed system can be used effectively to monitor and detect cardiovascular diseases.