Utilization of biomacromolecular in vitro assay systems in the prediction of in vivo toxic responses.

Lens and eye toxicity research Pub Date : 1992-01-01
V C Gordon
{"title":"Utilization of biomacromolecular in vitro assay systems in the prediction of in vivo toxic responses.","authors":"V C Gordon","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Target biomacromolecular assay systems utilize as endpoints quantifiable alterations in key macromolecules elicited by various chemicals and formulations. The EYTEX Assay System, an example of a target biomacromolecular test method, has been used to predict the in vivo ocular irritancy potential of chemicals and formulations. The biomacromolecular reagent is a standardized matrix which can be produced routinely. One hundred test chemicals, representing diverse chemical classes with a wide range of toxic responses in vivo, were evaluated in the EYTEX system. In vitro results were compared to maximum 24-hour Draize scores and Draize classifications. The concordance of the in vitro and in vivo results demonstrated the relevance of the alteration of the EYTEX macromolecular matrix to the prediction of in vivo ocular irritation. The relevance of the in vitro endpoint of turbidity of the EYTEX matrix to in vivo ocular irritation has thus been demonstrated for a large number of test agents in other evaluation studies (1, 2, 3, 4, 5, 6, 7, 8). Integration of macromolecular-based test methods with in vitro cytotoxicity or cellular response methods may provide complementary information about mechanisms of target-induced toxicity. The target biomacromolecular assay systems which provide standardized, reproducible reagents are valuable components of test batteries.</p>","PeriodicalId":17964,"journal":{"name":"Lens and eye toxicity research","volume":"9 3-4","pages":"211-27"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lens and eye toxicity research","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Target biomacromolecular assay systems utilize as endpoints quantifiable alterations in key macromolecules elicited by various chemicals and formulations. The EYTEX Assay System, an example of a target biomacromolecular test method, has been used to predict the in vivo ocular irritancy potential of chemicals and formulations. The biomacromolecular reagent is a standardized matrix which can be produced routinely. One hundred test chemicals, representing diverse chemical classes with a wide range of toxic responses in vivo, were evaluated in the EYTEX system. In vitro results were compared to maximum 24-hour Draize scores and Draize classifications. The concordance of the in vitro and in vivo results demonstrated the relevance of the alteration of the EYTEX macromolecular matrix to the prediction of in vivo ocular irritation. The relevance of the in vitro endpoint of turbidity of the EYTEX matrix to in vivo ocular irritation has thus been demonstrated for a large number of test agents in other evaluation studies (1, 2, 3, 4, 5, 6, 7, 8). Integration of macromolecular-based test methods with in vitro cytotoxicity or cellular response methods may provide complementary information about mechanisms of target-induced toxicity. The target biomacromolecular assay systems which provide standardized, reproducible reagents are valuable components of test batteries.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
生物大分子体外检测系统在体内毒性反应预测中的应用。
目标生物大分子分析系统利用由各种化学物质和制剂引起的关键大分子的可量化变化作为终点。EYTEX检测系统是靶生物大分子检测方法的一个例子,已被用于预测化学品和制剂的体内眼刺激电位。该生物大分子试剂是一种可常规生产的标准化基质。一百种测试化学品,代表不同的化学类别,在体内具有广泛的毒性反应,在EYTEX系统中进行了评估。体外结果与最大24小时Draize评分和Draize分类进行比较。体外和体内结果的一致性证明了EYTEX大分子基质的改变与体内眼刺激预测的相关性。因此,EYTEX基质浊度的体外终点与体内眼部刺激的相关性已经在其他评估研究中得到了大量测试试剂的证实(1,2,3,4,5,6,7,8)。将基于大分子的测试方法与体外细胞毒性或细胞反应方法相结合,可能会为靶标诱导毒性的机制提供补充信息。目标生物大分子分析系统提供标准化、可重复的试剂,是测试电池的重要组成部分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Role of toxic ingredients in silicone oils in the induction of increased corneal endothelial permeability. Induction of experimental proliferative vitreoretinopathy in the rabbit eye by intravitreal injections of fibroblast growth factor. Effects of Gingko biloba extracts in a model of tractional retinal detachment. The role of viscoelastics, cannulas, and irrigating solution additives in post-cataract surgery corneal edema: a brief review. Cytotoxicity of ophthalmic preservatives on human corneal epithelium.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1