Time-frequency analysis of narrow bipolar pulses observed in Sri Lanka

T. A. L. N. Gunasekara, S. Vayanganie, S. Jayalal, M. Fernando, D. Sonnadara, V. Cooray
{"title":"Time-frequency analysis of narrow bipolar pulses observed in Sri Lanka","authors":"T. A. L. N. Gunasekara, S. Vayanganie, S. Jayalal, M. Fernando, D. Sonnadara, V. Cooray","doi":"10.1109/ICLP.2016.7791401","DOIUrl":null,"url":null,"abstract":"Narrow Bipolar Pulses (NBP) of a single thunderstorm from a coastal location in Sri Lanka were subjected to S-transformation in order to study their time-frequency information. This study is an extension to a similar study carried out by the authors where properties of NBPs were analyzed using the wavelet transformation. Keeping in line with the previous study, 18 events pertaining to equal number of positive and negative NBPs with the narrowest temporal widths were studied. The data was obtained from the southern coastal area of Sri Lanka (Matara -5.95° N, 8.53° E) from a highly active thunderstorm, which occurred during the month of May in 2013. The waveforms were recorded with a 10 ns resolution within a 100 ms time window. The spanning (width) and the ratio of peak power amongst the initial and overshoot pulses were measured and compared for each polarity. The negative NBPs had an average spanning of 134-371 kHz. The overshoot of the same had an average range of 127-255 kHz. The positive NBPs had an average spanning of 103-245 kHz. The overshoot of the same had an average range of 102-195 kHz. The ratio of peak power of NBPs to overshoot had an average of 1.08 for both positive and negative pulses. The spectrogram reveals the initial and overshoots pulses to be relatively equal in power intensities.","PeriodicalId":373744,"journal":{"name":"2016 33rd International Conference on Lightning Protection (ICLP)","volume":"91 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 33rd International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2016.7791401","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Narrow Bipolar Pulses (NBP) of a single thunderstorm from a coastal location in Sri Lanka were subjected to S-transformation in order to study their time-frequency information. This study is an extension to a similar study carried out by the authors where properties of NBPs were analyzed using the wavelet transformation. Keeping in line with the previous study, 18 events pertaining to equal number of positive and negative NBPs with the narrowest temporal widths were studied. The data was obtained from the southern coastal area of Sri Lanka (Matara -5.95° N, 8.53° E) from a highly active thunderstorm, which occurred during the month of May in 2013. The waveforms were recorded with a 10 ns resolution within a 100 ms time window. The spanning (width) and the ratio of peak power amongst the initial and overshoot pulses were measured and compared for each polarity. The negative NBPs had an average spanning of 134-371 kHz. The overshoot of the same had an average range of 127-255 kHz. The positive NBPs had an average spanning of 103-245 kHz. The overshoot of the same had an average range of 102-195 kHz. The ratio of peak power of NBPs to overshoot had an average of 1.08 for both positive and negative pulses. The spectrogram reveals the initial and overshoots pulses to be relatively equal in power intensities.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
斯里兰卡观测到的窄双极脉冲时频分析
对斯里兰卡沿海地区一次雷暴的窄双极脉冲(NBP)进行s变换,研究其时频信息。本研究是作者利用小波变换分析nbp性质的类似研究的延伸。与之前的研究一致,我们研究了18个事件,这些事件与时间宽度最窄的阳性和阴性NBPs数量相同。数据来源于2013年5月斯里兰卡南部沿海地区(Matara -5.95°N, 8.53°E)的一次高度活跃雷暴。波形以10ns分辨率在100ms时间窗内记录。测量和比较了每个极性的初始脉冲和超调脉冲之间的跨越(宽度)和峰值功率比。负NBPs的平均跨度为134-371 kHz。同样的超调平均范围为127- 255khz。阳性NBPs的平均跨度为103-245 kHz。同样的超调有102-195千赫的平均范围。正脉冲和负脉冲的峰值功率与超调量之比平均为1.08。频谱图显示,初始脉冲和超调脉冲的功率强度相对相等。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental and theoretical evaluation of aluminium deflection due to lightning strikes Degradation characteristics on MOV of surge arrester used for 6.6kV power distribution line Lightning protection of a temporary structure in open area Lightning performance of EHV and UHV overhead transmission Lines in China southern power grid Research of influence pattern of lightning current on impulse characteristic of ground device for pole and tower
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1