{"title":"Feasibility study of using two 3-D position sensitive CZT detectors for small animal PET","authors":"Feng Zhang, Zhong He, Dan Xu, Ling-Jian Meng","doi":"10.1109/NSSMIC.2005.1596621","DOIUrl":null,"url":null,"abstract":"An experimental small animal PET using two 3-D position sensitive CdZnTe detectors was developed and tested. Each 1.5/spl times/1.5/spl times/1 cm/sup 3/ CdZnTe detector employs 11 by 11 pixellated anodes wire-bonded to the VAS3.1/TAT3/MCR3 readout electronics. Each detector can obtain the deposited energy and 3-D coordinates for single-pixel and multiple-pixel events. Both systems achieved energy resolutions of better than 1.0% FWHM at 662 ReV for single-pixel events and better than 1.5% FWHM at 662 ReV for two-pixel events. The position resolution of each detector was estimated to be /spl sim/1.3/spl times/1.3/spl times/0.5 mm/sup 3/. Modifications to the firmware of the readout board and additions of custom-built circuitry enabled coincidence measurement between two 3-D CdZnTe detector systems using VAS3.1/TAT3/MCR3 readout systems. Spatial resolution improvements by using depth of interaction (DOI) and by identifying the first interaction using Compton scattering angle reconstruction are reported and discussed.","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium Conference Record, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2005.1596621","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17
Abstract
An experimental small animal PET using two 3-D position sensitive CdZnTe detectors was developed and tested. Each 1.5/spl times/1.5/spl times/1 cm/sup 3/ CdZnTe detector employs 11 by 11 pixellated anodes wire-bonded to the VAS3.1/TAT3/MCR3 readout electronics. Each detector can obtain the deposited energy and 3-D coordinates for single-pixel and multiple-pixel events. Both systems achieved energy resolutions of better than 1.0% FWHM at 662 ReV for single-pixel events and better than 1.5% FWHM at 662 ReV for two-pixel events. The position resolution of each detector was estimated to be /spl sim/1.3/spl times/1.3/spl times/0.5 mm/sup 3/. Modifications to the firmware of the readout board and additions of custom-built circuitry enabled coincidence measurement between two 3-D CdZnTe detector systems using VAS3.1/TAT3/MCR3 readout systems. Spatial resolution improvements by using depth of interaction (DOI) and by identifying the first interaction using Compton scattering angle reconstruction are reported and discussed.