Characteristics of Overheated Electrical Joints Due to Loose Connection

Xin Zhou, T. Schoepf
{"title":"Characteristics of Overheated Electrical Joints Due to Loose Connection","authors":"Xin Zhou, T. Schoepf","doi":"10.1109/HOLM.2011.6034795","DOIUrl":null,"url":null,"abstract":"Abstract - Overheated electrical joints due to loose connection are often precursors of electric fires, arc faults, and arc flash in electrical systems. This paper is about the formation mechanism and behavior characteristics of loose connection induced overheated electrical joints. Specific experiments were conducted on busbar joints and systems with currents ranging from 100 A up to 5000 A. The lead time of the overheated contact formation is significantly impacted by the tightening torque of busbar bolts, the amplitude of current, and the proper sizing of electrical joints.","PeriodicalId":197233,"journal":{"name":"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)","volume":"85 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.2011.6034795","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Abstract - Overheated electrical joints due to loose connection are often precursors of electric fires, arc faults, and arc flash in electrical systems. This paper is about the formation mechanism and behavior characteristics of loose connection induced overheated electrical joints. Specific experiments were conducted on busbar joints and systems with currents ranging from 100 A up to 5000 A. The lead time of the overheated contact formation is significantly impacted by the tightening torque of busbar bolts, the amplitude of current, and the proper sizing of electrical joints.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
连接松动引起的电气接头过热的特点
摘要:在电气系统中,由于连接松动引起的电气接头过热往往是电气火灾、电弧故障和电弧闪光的先兆。本文研究了松动连接引起的电气接头过热的形成机理和行为特征。具体的实验进行了母线接头和系统的电流范围从100到5000 A。母线螺栓的拧紧力矩、电流的幅值以及电气接头的合适尺寸对过热触点形成的提前时间有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Study on Mobile Communication Device Structure Design Resisting Dust Particles Ingress High Current Arc Erosion on Copper Electrodes in Air Contact Resistance Characteristics of Relays Operated in Silicone-Vapor-Containing and Non-Silicone Atmospheres with Different Electrical Load Conditions The Influence of the Organic Compounds on the Contaminated Electrical Contacts There is Tin and there is Tin - Characterisation of Tribological and Electrical Properties of Electroplated Tin Surfaces
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1