A PMU-based Protection Relay In The Presence of STATCOM

Kiruthiga Manoharan, S. Periasamy, Kumudini Devi Raguru Pandu
{"title":"A PMU-based Protection Relay In The Presence of STATCOM","authors":"Kiruthiga Manoharan, S. Periasamy, Kumudini Devi Raguru Pandu","doi":"10.1109/PECCON55017.2022.9851165","DOIUrl":null,"url":null,"abstract":"The transmission line compensated with STATCOM affects the operation of protection relays in the system. In this context the effect of Static Synchronous Compensator on loss of field failure protection is analyzed. The existence of STATCOM has a pernicious effect on the operating time of generator field failure relay. To reduce the adverse effect of STATCOM a new phasor measurement unit based loss of excitation protection scheme is modelled in MATLAB/SIMULINK. Phasor measurement unit are high speed sensors that are used to estimate the magnitude and phase angle at a rate of 48 samples per cycle which makes it to detect fluctuations in voltage or current. The effect of STATCOM on PMU based LOE protection scheme are analysed for complete field failure and partial loss of field failure. The simulation results depicts that a new phasor measurement unit based LOE protection relay detects and operates the field failure protection relay even in the existence of Static Synchronous Compensator in transmission line.","PeriodicalId":129147,"journal":{"name":"2022 International Virtual Conference on Power Engineering Computing and Control: Developments in Electric Vehicles and Energy Sector for Sustainable Future (PECCON)","volume":"129 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Virtual Conference on Power Engineering Computing and Control: Developments in Electric Vehicles and Energy Sector for Sustainable Future (PECCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECCON55017.2022.9851165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The transmission line compensated with STATCOM affects the operation of protection relays in the system. In this context the effect of Static Synchronous Compensator on loss of field failure protection is analyzed. The existence of STATCOM has a pernicious effect on the operating time of generator field failure relay. To reduce the adverse effect of STATCOM a new phasor measurement unit based loss of excitation protection scheme is modelled in MATLAB/SIMULINK. Phasor measurement unit are high speed sensors that are used to estimate the magnitude and phase angle at a rate of 48 samples per cycle which makes it to detect fluctuations in voltage or current. The effect of STATCOM on PMU based LOE protection scheme are analysed for complete field failure and partial loss of field failure. The simulation results depicts that a new phasor measurement unit based LOE protection relay detects and operates the field failure protection relay even in the existence of Static Synchronous Compensator in transmission line.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
STATCOM存在时基于pmu的保护继电器
用STATCOM补偿的传输线影响系统中保护继电器的工作。在此基础上,分析了静态同步补偿器对现场失效保护损耗的影响。STATCOM的存在对发电机励磁故障继电器的工作时间有很大的影响。为了减少STATCOM的不利影响,在MATLAB/SIMULINK中建立了一种新的基于相量测量单元的失磁保护方案。相量测量单元是高速传感器,用于以每周期48个样本的速率估计幅度和相角,使其能够检测电压或电流的波动。分析了现场完全失效和局部失效时,STATCOM对基于PMU的LOE保护方案的影响。仿真结果表明,一种新的基于相量测量单元的LOE保护继电器在存在静态同步补偿器的情况下也能检测出现场故障保护继电器并进行操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Energy Storage System with Artificial Neural Networks using PI Hybrid Controllers Review and Analysis of Techniques to Mitigate Sub Synchronous Resonance using FACTS Devices 12-Pulse Power Inverter with Fixed Switching Angle for Grid-connected PV Array TWO-STAGE VOLTAGE REGULATOR FED VOLTAGE CONTROL USING PIC MICRO CONTROLLER Performance Assessment of Grey Wolf Technique for AGC of Multi-source Intertied System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1