Supervisory control of convertible static transmission controller in shunt-shunt mode of operation

N. Yousefpoor, Sungmin Kim, S. Bhattacharya, B. Parkhideh
{"title":"Supervisory control of convertible static transmission controller in shunt-shunt mode of operation","authors":"N. Yousefpoor, Sungmin Kim, S. Bhattacharya, B. Parkhideh","doi":"10.1109/IECON.2013.6699322","DOIUrl":null,"url":null,"abstract":"The Convertible static transmission controller is a versatile device which can be installed across a transmission transformer to extend the life time of existing transformers by partially bypassing and conditioning the substation throughput power. The proposed technology can provide several integration options with multiple operational modes. From the supervisory control point of view, a control algorithm is required to set the reference values of active and reactive power flow of CSTC converters based on the desired operating points for transformer active and reactive power. In this paper, the algebraic model of CSTC in shunt-shunt mode of operation is derived. Algebraic model of CSTC is used for steady state and transient stability analysis. Algebraic model will present the behavior of transformer power flow with respect to various operating points of CSTC converters. The P-Q transformer operating range can be obtained based on the proposed algebraic model. Dynamic performance of the CSTC system is also investigated in PSCAD/EMTDC environment. Simulation results will be presented to verify the proposed algebraic model of CSTC in shunt-shunt mode of operation based on steady state results.","PeriodicalId":237327,"journal":{"name":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2013.6699322","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The Convertible static transmission controller is a versatile device which can be installed across a transmission transformer to extend the life time of existing transformers by partially bypassing and conditioning the substation throughput power. The proposed technology can provide several integration options with multiple operational modes. From the supervisory control point of view, a control algorithm is required to set the reference values of active and reactive power flow of CSTC converters based on the desired operating points for transformer active and reactive power. In this paper, the algebraic model of CSTC in shunt-shunt mode of operation is derived. Algebraic model of CSTC is used for steady state and transient stability analysis. Algebraic model will present the behavior of transformer power flow with respect to various operating points of CSTC converters. The P-Q transformer operating range can be obtained based on the proposed algebraic model. Dynamic performance of the CSTC system is also investigated in PSCAD/EMTDC environment. Simulation results will be presented to verify the proposed algebraic model of CSTC in shunt-shunt mode of operation based on steady state results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
并联工作模式下可转换静态传动控制器的监控
可转换静态传输控制器是一种多功能装置,可以安装在传输变压器上,通过部分旁路和调节变电站的吞吐量来延长现有变压器的使用寿命。所提出的技术可以提供具有多种操作模式的多种集成选项。从监督控制的角度来看,需要一种控制算法,根据变压器有功和无功的期望工作点来设定CSTC变流器有功和无功潮流的参考值。本文推导了并联运行模式下CSTC的代数模型。采用CSTC的代数模型进行稳态和暂态稳定分析。用代数模型来表示CSTC变流器各工作点的变压器潮流特性。根据所提出的代数模型,可以得到P-Q变压器的工作范围。研究了CSTC系统在PSCAD/EMTDC环境下的动态性能。仿真结果将验证基于稳态结果的并联运行模式下CSTC的代数模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Improving 3D scan matching time of the coarse binary cubes method with fast spatial subsampling Fault-tolerant operation of an open-end winding five-phase PMSM drive with inverter faults Large scale micro-macro bilateral control using piezoelectric cantilever with plant nominalization A study on methods to design and select energy storage devices for Fuel Cell hybrid powered railway vehicles Development of a half-circle-shaped tubular permanent magnet machine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1