{"title":"Thermo-mechanical analysis of a prototypical SiC foam-based flow channel insert","authors":"S. Sharafat, A. Aoyama, N. Morley, N. Ghoniem, B. Williams, Y. Katoh","doi":"10.1109/FUSION.2009.5226527","DOIUrl":null,"url":null,"abstract":"As part of the US ITER Test Blanket Module development effort several FCI concepts using a variety of porous SiC and SiC/SiC composites are being developed. In this work we report on the thermo-mechanical analysis of a SiC foam-based FCI. Prototypes of FCI segments as large as 0.12 m × 0.75 m × 0.015 m were recently fabricated and heat tested with a maximum ΔT of ∼150 °C across the FCI walls. No visible damage was observed after testing. A detailed thermo-mechanical analysis of the test was conducted and results of the simulations are discussed in context of actual FCI operating conditions.","PeriodicalId":236460,"journal":{"name":"2009 23rd IEEE/NPSS Symposium on Fusion Engineering","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 23rd IEEE/NPSS Symposium on Fusion Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FUSION.2009.5226527","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

As part of the US ITER Test Blanket Module development effort several FCI concepts using a variety of porous SiC and SiC/SiC composites are being developed. In this work we report on the thermo-mechanical analysis of a SiC foam-based FCI. Prototypes of FCI segments as large as 0.12 m × 0.75 m × 0.015 m were recently fabricated and heat tested with a maximum ΔT of ∼150 °C across the FCI walls. No visible damage was observed after testing. A detailed thermo-mechanical analysis of the test was conducted and results of the simulations are discussed in context of actual FCI operating conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
碳化硅泡沫基流道嵌件原型的热力学分析
作为美国ITER测试包层模块开发工作的一部分,正在开发几种使用各种多孔SiC和SiC/SiC复合材料的FCI概念。在这项工作中,我们报告了基于SiC泡沫的FCI的热力学分析。最近制造了尺寸为0.12 m × 0.75 m × 0.015 m的FCI段原型,并在FCI壁上进行了最高ΔT ~ 150°C的热测试。试验后未见明显损伤。对试验进行了详细的热力学分析,并结合FCI的实际工况对模拟结果进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Advantages of high tolerance measurements in fusion environments applying photogrammetry Structural design of the iter ec upper launcher Simulation experiment of thermal transient events in ITER by use of magneti zed coaxial plasma gun Transient thermal and stress response of a helium-cooled tungsten plate-type divertor Results of Compact Stellarator engineering trade studies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1