Detection of three visual impairments: Strabismus, blind spots, and blurry vision in rural areas using Raspberry PI by implementing hirschberg, visual field, and visual acuity tests

A. Paglinawan, Marianne M. Sejera, C. Paglinawan, Ryan Elbert H. Ancheta, Nicole Jan D. Guatato, Rey James H. Nava, Kimberly P. Sison
{"title":"Detection of three visual impairments: Strabismus, blind spots, and blurry vision in rural areas using Raspberry PI by implementing hirschberg, visual field, and visual acuity tests","authors":"A. Paglinawan, Marianne M. Sejera, C. Paglinawan, Ryan Elbert H. Ancheta, Nicole Jan D. Guatato, Rey James H. Nava, Kimberly P. Sison","doi":"10.1109/HNICEM.2017.8269550","DOIUrl":null,"url":null,"abstract":"This paper introduces an integrated way of detecting common visual impairments namely: Strabismus, Blind Spots and Blurry Vision. According to the Chairman of National Committee on Site Preservation, 70% of ophthalmologists are found in urban areas while the remaining 30% is scattered to rural areas. Thus, a low cost and portable product that can efficiently and effectively detect the said impairments is necessary. In addition to this, the device need not be operated by a medical practitioner. A Raspberry Pi with a monitor and camera would be used to implement Hirschberg Test for Strabismus, Visual Field Test for Blind Spot and Visual Acuity Tests for Blurry Vision. Hirschberg Test is implemented by taking the Central Corneal Light Reflex Ratio (CCLRR) of the patient through a picture taken from them. Visual Field test is done by presenting stimuli at different area of the visual field and recording the patient's response through a button press. The Visual Acuity test is done by using a Landolt C optotype and recording the patient's response through an 8 button keypad. The results from the Hirschberg Test were computed to have an accuracy of 90% by using z-test. For the Visual Field test and Visual Acuity test, the Mann Whitney Test proved that the data gathered from the patients had no significant difference with that from the medical records of patients.","PeriodicalId":104407,"journal":{"name":"2017IEEE 9th International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment and Management (HNICEM)","volume":"99 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017IEEE 9th International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment and Management (HNICEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HNICEM.2017.8269550","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

This paper introduces an integrated way of detecting common visual impairments namely: Strabismus, Blind Spots and Blurry Vision. According to the Chairman of National Committee on Site Preservation, 70% of ophthalmologists are found in urban areas while the remaining 30% is scattered to rural areas. Thus, a low cost and portable product that can efficiently and effectively detect the said impairments is necessary. In addition to this, the device need not be operated by a medical practitioner. A Raspberry Pi with a monitor and camera would be used to implement Hirschberg Test for Strabismus, Visual Field Test for Blind Spot and Visual Acuity Tests for Blurry Vision. Hirschberg Test is implemented by taking the Central Corneal Light Reflex Ratio (CCLRR) of the patient through a picture taken from them. Visual Field test is done by presenting stimuli at different area of the visual field and recording the patient's response through a button press. The Visual Acuity test is done by using a Landolt C optotype and recording the patient's response through an 8 button keypad. The results from the Hirschberg Test were computed to have an accuracy of 90% by using z-test. For the Visual Field test and Visual Acuity test, the Mann Whitney Test proved that the data gathered from the patients had no significant difference with that from the medical records of patients.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过hirschberg、视野和视力测试检测三种视觉障碍:斜视、盲点和农村视力模糊
本文介绍了一种综合检测常见视觉障碍即斜视、盲点和视觉模糊的方法。据全国遗址保护委员会主席介绍,70%的眼科医生分布在城市地区,其余30%分散在农村地区。因此,需要一种低成本和便携的产品,可以高效和有效地检测所述损伤。除此之外,该装置不需要由医生操作。一个带有监视器和摄像头的树莓派将用于执行斜视的赫施伯格测试,盲点的视野测试和视觉模糊的视力测试。Hirschberg测试是通过拍摄患者的照片来测量患者的中央角膜光反射比(CCLRR)。视野测试是通过在视野的不同区域提供刺激,并通过按下按钮记录患者的反应来完成的。视力测试是通过使用Landolt C视型仪,并通过一个8键键盘记录患者的反应来完成的。使用z检验计算Hirschberg检验结果的准确率为90%。对于视野测试和视力测试,Mann Whitney test证明从患者身上收集的数据与患者病历上的数据没有显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Real-time flood water level monitoring system with SMS notification Energy audit and analysis of the electricity consumption of an educational building in the Philippines for smart consumption Microcontroller and app-based air quality monitoring system for particulate matter 2.5 (PM2.5) and particulate matter 1 (PM1) TRANSPRO: An educational tool for the design and analysis of power transmission lines Sitting posture assessment using computer vision
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1