Monte Carlo simulations on GPU for brachytherapy applications

Y. Lemaréchal, J. Bert, N. Boussion, E. Le Fur, D. Visvikis
{"title":"Monte Carlo simulations on GPU for brachytherapy applications","authors":"Y. Lemaréchal, J. Bert, N. Boussion, E. Le Fur, D. Visvikis","doi":"10.1109/NSSMIC.2013.6829314","DOIUrl":null,"url":null,"abstract":"In brachytherapy, dosimetric plans are routinely calculated with the TG43 formalism which considers the patient as a simple water box. However, accurate modelling of the physical processes considering patient heterogeneity using Monte Carlo (MC) methods is currently too time-consuming and computationally demanding to be routinely used. As a solution we implemented an accurate and fast MC simulation based on Geant4 on graphics processing units (GPU) for brachytherapy applications. Existing approaches using GPU architecture for brachytherapy MC simulations suffer from numerous approximations including, the use of virtual seed bound to a phase space file to define dwell sources, or removing voxel within the CT image to include seed density. Within the proposed framework such approximations have been removed. A comparison between dosimetric plans based on the current clinical standard (TG43) and the proposed full MC simulation led to substantial differences due to the TG43 related approximations assuming the patient as a water box. Finally, the proposed dosimetry platform is capable of providing accurate dose distributions within one minute, which is compatible for a clinical routine usage.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2013.6829314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

In brachytherapy, dosimetric plans are routinely calculated with the TG43 formalism which considers the patient as a simple water box. However, accurate modelling of the physical processes considering patient heterogeneity using Monte Carlo (MC) methods is currently too time-consuming and computationally demanding to be routinely used. As a solution we implemented an accurate and fast MC simulation based on Geant4 on graphics processing units (GPU) for brachytherapy applications. Existing approaches using GPU architecture for brachytherapy MC simulations suffer from numerous approximations including, the use of virtual seed bound to a phase space file to define dwell sources, or removing voxel within the CT image to include seed density. Within the proposed framework such approximations have been removed. A comparison between dosimetric plans based on the current clinical standard (TG43) and the proposed full MC simulation led to substantial differences due to the TG43 related approximations assuming the patient as a water box. Finally, the proposed dosimetry platform is capable of providing accurate dose distributions within one minute, which is compatible for a clinical routine usage.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
近距离治疗应用的GPU蒙特卡罗模拟
在近距离治疗中,剂量计计划通常使用TG43形式计算,该形式将患者视为一个简单的水盒。然而,使用蒙特卡罗(MC)方法对考虑患者异质性的物理过程进行精确建模目前过于耗时且计算要求高,无法常规使用。作为解决方案,我们在图形处理单元(GPU)上实现了基于Geant4的精确和快速的MC模拟,用于近距离治疗应用。使用GPU架构进行近距离放射治疗MC模拟的现有方法存在许多近似问题,包括使用绑定到相空间文件的虚拟种子来定义居住源,或在CT图像中删除体素以包含种子密度。在拟议的框架内,这种近似已被取消。基于当前临床标准(TG43)的剂量学计划与拟议的全MC模拟之间的比较导致了实质性的差异,因为TG43相关的近似假设患者是一个水盒。最后,提出的剂量测定平台能够在一分钟内提供准确的剂量分布,这与临床常规使用兼容。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Scientific Trigger Unit for space-based real-time gamma ray burst detection I - Scientific software model and simulations Study on two-cell rf-deflector cavity for ultra-short electron bunch measurement Applications of many-core technologies to on-line event reconstruction in High Energy Physics experiments Optimization of the gas system in the CMS RPC detector at the LHC Performance of the ATLAS calorimeter trigger in the LHC Run 1 data taking period
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1