{"title":"BTLBO Based SPMUs Placement Optimization for Fault Observation in Power Grid","authors":"A. Zitouni, H. Bentarzi","doi":"10.51485/ajss.v4i1.78","DOIUrl":null,"url":null,"abstract":"The placement of synchro-phasor measurement units in electric transmission systems has also gained much attention for enhancing the control as well as the protection scheme. In this research work, a binary teaching learning based optimization (BTLBO) algorithm for the optimal placement of synchro-phasor measurement units (SPMUs) is proposed. The optimal PMU placement problem is formulated to minimize the number of SPMUs installation subject to full network observability of the power system buses under fault conditions. The effectiveness of the proposed method is verified by the simulation of IEEE 14-bus benchmark system.","PeriodicalId":153848,"journal":{"name":"Algerian Journal of Signals and Systems","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Algerian Journal of Signals and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51485/ajss.v4i1.78","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The placement of synchro-phasor measurement units in electric transmission systems has also gained much attention for enhancing the control as well as the protection scheme. In this research work, a binary teaching learning based optimization (BTLBO) algorithm for the optimal placement of synchro-phasor measurement units (SPMUs) is proposed. The optimal PMU placement problem is formulated to minimize the number of SPMUs installation subject to full network observability of the power system buses under fault conditions. The effectiveness of the proposed method is verified by the simulation of IEEE 14-bus benchmark system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于BTLBO的电网故障观测spmu布局优化
同步相量测量装置在电力传输系统中的位置也受到了人们的关注,以提高控制和保护方案。在本研究中,提出了一种基于二元教学的优化算法(BTLBO),用于同步相量测量单元(spmu)的优化放置。提出了PMU的最优配置问题,以保证故障情况下电力系统母线的全网络可观测性,使PMU的安装数量最少。通过对IEEE 14总线基准系统的仿真验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Energy Management System in Smart Micro-Grid Impact of Voltage Temperature Coefficient on power prediction of four type silicon photovoltaic module technologies installed in real conditions in the north-central of Algeria PD adaptive controller method for a three-axis stabilized rigid satellite attitude system DFIG Wind Turbine Controlled by Sliding Mode and Fuzzy-Sliding Control Modes Design and simulation of Demodulator Based BELL-202 standard for NanoSatellite Communication Sub-system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1