Electrical equipment at a modern seamless tube mill

J. Cowan, D.S. Rihal, R.R. Smylie
{"title":"Electrical equipment at a modern seamless tube mill","authors":"J. Cowan, D.S. Rihal, R.R. Smylie","doi":"10.1109/IAS.1988.25210","DOIUrl":null,"url":null,"abstract":"A description is given of major electrical equipment installed at a seamless-tube mill and some of the considerations that influenced its selection and design. The initial design work to rationalize different mill builders' requirements and thus reduce the spares inventory is described. The equipment includes main DC motors and drives totaling some 20 MW for the piercer, mandrel, and stretch reducing mills. Of particular interest is a 1.6 MW low-inertia six-armature DC drive for the mandrel rack. Other equipment includes auxiliary DC drives, variable-frequency drives for roller tables, 15 Hz generating sets, and dry-type cast coil transformers. Control and automation uses eleven programmable controllers for logic sequences and mill automation and eleven microprocessors for operator interface and complex control functions.<<ETX>>","PeriodicalId":274766,"journal":{"name":"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1988.25210","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A description is given of major electrical equipment installed at a seamless-tube mill and some of the considerations that influenced its selection and design. The initial design work to rationalize different mill builders' requirements and thus reduce the spares inventory is described. The equipment includes main DC motors and drives totaling some 20 MW for the piercer, mandrel, and stretch reducing mills. Of particular interest is a 1.6 MW low-inertia six-armature DC drive for the mandrel rack. Other equipment includes auxiliary DC drives, variable-frequency drives for roller tables, 15 Hz generating sets, and dry-type cast coil transformers. Control and automation uses eleven programmable controllers for logic sequences and mill automation and eleven microprocessors for operator interface and complex control functions.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
现代无缝管厂的电气设备
介绍了某无缝管厂安装的主要电气设备,以及影响其选择和设计的一些考虑因素。描述了初步设计工作,以使不同的轧机制造商的要求合理化,从而减少备件库存。该设备包括主要的直流电机和驱动器,共计约20兆瓦,用于穿孔机,心轴和拉伸机。特别感兴趣的是一个1.6兆瓦的低惯性六电枢直流驱动的心轴架。其他设备包括辅助直流驱动器,滚动台的变频驱动器,15赫兹发电机组和干式铸圈变压器。控制和自动化使用11个可编程控制器进行逻辑序列和工厂自动化,11个微处理器用于操作界面和复杂的控制功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Zero voltage fired, transformer coupled thyristor power control applied for temperature control of the tin bath in the float glass process Remote fault/smoke detection for motor control centers An improved direct AC-AC converter and its application to three phase induction motor drive An improved resonant DC link invertor for induction motor drives Bipolar charging of particles in the 1 to 10 mu m diameter size range
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1